In recent years, a considerable effort has been made to minimize the size of dc-link capacitors in single-phase active front ends (SP-AFEs), to reduce cost, and to increase power density. As a result of the lower energy storage, a high-bandwidth outer dc voltage control loop is required to respond to fast load changes. Linearized modeling is usually performed according to the power-balance method and the control is designed using LTI techniques. This is done assuming negligible voltage ripple at twice the grid frequency, and the model is considered valid up to the grid frequency. However, its precise validity limits are usually unknown and the control design becomes empirical when approaching these boundaries. To overcome this drawback, linear time-periodic (LTP) theory can be exploited, defining the range of validity of the LTI model and providing precise stability boundaries for the dc-link voltage loop. The main result is that LTP models more accurately describe the system behavior and provide superior results compared to the LTI ones. Theoretical analysis, simulations, and extensive experimental tests on a 10-kW converter are presented to validate the claims. © 2013 IEEE.

Stability assessment of high-bandwidth DC voltage controllers in single-phase active front ends: LTI Versus LTP Models

Zanchetta P.
2018-01-01

Abstract

In recent years, a considerable effort has been made to minimize the size of dc-link capacitors in single-phase active front ends (SP-AFEs), to reduce cost, and to increase power density. As a result of the lower energy storage, a high-bandwidth outer dc voltage control loop is required to respond to fast load changes. Linearized modeling is usually performed according to the power-balance method and the control is designed using LTI techniques. This is done assuming negligible voltage ripple at twice the grid frequency, and the model is considered valid up to the grid frequency. However, its precise validity limits are usually unknown and the control design becomes empirical when approaching these boundaries. To overcome this drawback, linear time-periodic (LTP) theory can be exploited, defining the range of validity of the LTI model and providing precise stability boundaries for the dc-link voltage loop. The main result is that LTP models more accurately describe the system behavior and provide superior results compared to the LTI ones. Theoretical analysis, simulations, and extensive experimental tests on a 10-kW converter are presented to validate the claims. © 2013 IEEE.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1349194
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 8
social impact