Abstract: The possibility of using electron paramagnetic resonance spectroscopy in Fricke (ferrous sulfate solution) dosimetry was investigated. Specifically, the spectra of different solutions mimicking irradiated dosimeters were recorded to study the shape and the intensity of the absorption peak with respect to the ferric ion concentration. The experimental data were used to identify a possible dosimetric signal, to check its linearity and to compute the sensitivity to the absorbed dose. The application of electron paramagnetic resonance in Fricke dosimetry appears to be feasible and the contribution to the combined standard uncertainty due to the measurement of the dosimetric signal is preliminary evaluated at Gy level in a range between zero and a few hundreds of Gy. Estratto: Si è verificata la possibilità di utilizzare la spettroscopia di risonanza paramagnetica elettronica nella dosimetria Fricke (soluzione di solfato ferroso). In particolare, abbiamo registrato gli spettri di diverse soluzioni che simulano dosimetri irraggiati per studiare la forma e l’intensità dei picchi di assorbimento rispetto alla concentrazione dello ione ferrico. I dati acquisiti sono stati usati per identificare un possibile segnale dosimetrico, per verificare la linearità e per calcolare la sensibilità alla dose assorbita. L’utilizzo della risonanza paramagnetica elettronica nella dosimetria Fricke sembra essere fattibile e il contributo all’incertezza standard dovuta alla misura del segnale dosimetrico è preliminarmente valutata a livello di Gy in un intervallo tra zero e poche centinaia di Gy.

Use of Electron Paramagnetic Resonance spectroscopy in Fricke dosimetry: measurement signal and achievable sensitivity.

DONDI, DANIELE;ODDONE, MASSIMO;
2014-01-01

Abstract

Abstract: The possibility of using electron paramagnetic resonance spectroscopy in Fricke (ferrous sulfate solution) dosimetry was investigated. Specifically, the spectra of different solutions mimicking irradiated dosimeters were recorded to study the shape and the intensity of the absorption peak with respect to the ferric ion concentration. The experimental data were used to identify a possible dosimetric signal, to check its linearity and to compute the sensitivity to the absorbed dose. The application of electron paramagnetic resonance in Fricke dosimetry appears to be feasible and the contribution to the combined standard uncertainty due to the measurement of the dosimetric signal is preliminary evaluated at Gy level in a range between zero and a few hundreds of Gy. Estratto: Si è verificata la possibilità di utilizzare la spettroscopia di risonanza paramagnetica elettronica nella dosimetria Fricke (soluzione di solfato ferroso). In particolare, abbiamo registrato gli spettri di diverse soluzioni che simulano dosimetri irraggiati per studiare la forma e l’intensità dei picchi di assorbimento rispetto alla concentrazione dello ione ferrico. I dati acquisiti sono stati usati per identificare un possibile segnale dosimetrico, per verificare la linearità e per calcolare la sensibilità alla dose assorbita. L’utilizzo della risonanza paramagnetica elettronica nella dosimetria Fricke sembra essere fattibile e il contributo all’incertezza standard dovuta alla misura del segnale dosimetrico è preliminarmente valutata a livello di Gy in un intervallo tra zero e poche centinaia di Gy.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/902634
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact