In this paper, two procedures for assessing water demand shortfalls following segment isolation are compared. The first (topological) procedure is based on a simple topological network analysis, and identifies the water demand shortfall as the water demand (under normal operational conditions) relative to the directly and/or indirectly isolated segment (s). The second (hydraulic) procedure is based on a pressure-driven hydraulic simulation of the network after segment isolation. Each of the two procedures was applied to two case studies, and the reliability (expressed in terms of maximum D-max and weighted average (D) over bar water demand shortfall) and economic burden (expressed in terms of number N-val or cost C-val of installed valves) of the resulting isolation valve system solution were compared. As a whole, the results show that network analysis and redesign are affected by the choice of the global variables (D-max or (D) over bar) used to characterize the demand shortfalls in network segments. Analysis of the case studies is followed by a discussion of the rationale behind the choice between the two procedures, which needs to balance accurate demand shortfall characterization with limited computation times, particularly in the multi-objective design stage.

Evaluating Water Demand Shortfalls in Segment Analysis

CREACO, ENRICO FORTUNATO;FRANCHINI, MARCO;
2012-01-01

Abstract

In this paper, two procedures for assessing water demand shortfalls following segment isolation are compared. The first (topological) procedure is based on a simple topological network analysis, and identifies the water demand shortfall as the water demand (under normal operational conditions) relative to the directly and/or indirectly isolated segment (s). The second (hydraulic) procedure is based on a pressure-driven hydraulic simulation of the network after segment isolation. Each of the two procedures was applied to two case studies, and the reliability (expressed in terms of maximum D-max and weighted average (D) over bar water demand shortfall) and economic burden (expressed in terms of number N-val or cost C-val of installed valves) of the resulting isolation valve system solution were compared. As a whole, the results show that network analysis and redesign are affected by the choice of the global variables (D-max or (D) over bar) used to characterize the demand shortfalls in network segments. Analysis of the case studies is followed by a discussion of the rationale behind the choice between the two procedures, which needs to balance accurate demand shortfall characterization with limited computation times, particularly in the multi-objective design stage.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1106404
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 31
social impact