In this paper, a detailed study on the local real time control of moveable sharp-crested weirs in sewer channels is presented. Firstly, an experimental analysis aimed at determining the hydraulic behaviour of the regulator under both free flow and submerged flow conditions was carried out. Then, a numerical investigation into the calibration of proportional (P) controllers for the weir control was performed. In particular, suitable values were evaluated for the controller proportional parameter in order to obtain quick regulations and avoid the occurrence of permanent water level oscillations behind the weir. A dimensionless approach was adopted for the generalisation of the results.

P controller calibration for the real time control of moveable weirs in sewer channels

CREACO, ENRICO FORTUNATO;MODICA, CARLO
2009-01-01

Abstract

In this paper, a detailed study on the local real time control of moveable sharp-crested weirs in sewer channels is presented. Firstly, an experimental analysis aimed at determining the hydraulic behaviour of the regulator under both free flow and submerged flow conditions was carried out. Then, a numerical investigation into the calibration of proportional (P) controllers for the weir control was performed. In particular, suitable values were evaluated for the controller proportional parameter in order to obtain quick regulations and avoid the occurrence of permanent water level oscillations behind the weir. A dimensionless approach was adopted for the generalisation of the results.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1106420
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact