Two analytical methods (HPLC-fluorimeter [HPLC-FLD] and tandem mass spectrometry LC/MS/MS) are available to assay phenyl-hydroxyethylmercapturic acids (PHEMAs), the mercapturic acids of styrene in humans. In the past, each method was used to check different populations of subjects, but until now no attempt has been made to compare the two methods. This study was designed to verify whether the two methods actually give comparable results. The influence of different conditions of sample storagein altering the concentration of PHEMAs was also investigated. Urine samples were collected at the beginning and at the end of the workshift from 10 workers exposed to different levels of styrene. Each sample was analysed both by LC/MS/MS after storage under different conditions (respectively, at −20 and +4 ◦C, and after repeated freezing–thawing cycles), and by HPLC-FLD (in thesame conditions of storage). Strong correlations were found between the two methods both for total PHEMAs and for each of the isomers measured, including the minor (S,R)-M1. Also an alternative approach, the Bland–Altman test, confirmed the agreement between the two methods. The different storage conditions tested did not decrease the concentration of PHEMAs but, surprisingly, a clear trend to increase was shown, particularly for (R,R)-M1, (S,R)-M2 and (R,R)-M2 in samples stored at +4 ◦C for 1 week. In conclusion, the study demonstrates that the methods give comparable results. Indirectly, this confirms also the main characteristics of PHEMAs, showed in the previous experiments: lowbiotransformation rates of styrene into PHEMAs; large inter-individual variability; and the presence of a clear preference in the excretion of the isomers deriving from (S)-styrene oxide. PHEMAs appear stable under different storage conditions, but further studies are needed to explain the increase of levels that occurs when samples are not kept frozen. To avoid pre-analytical errors, samples collected for biomonitoring or research purposes should be frozen as soon as possible, and thawed only one time just before the analysis.

Mercapturic acids of styrene in man: comparability of the results obtained by LC/MS/MS and by HPLC-fluorimeter, and stability of samples under different storage conditions

IMBRIANI, MARCELLO
2006-01-01

Abstract

Two analytical methods (HPLC-fluorimeter [HPLC-FLD] and tandem mass spectrometry LC/MS/MS) are available to assay phenyl-hydroxyethylmercapturic acids (PHEMAs), the mercapturic acids of styrene in humans. In the past, each method was used to check different populations of subjects, but until now no attempt has been made to compare the two methods. This study was designed to verify whether the two methods actually give comparable results. The influence of different conditions of sample storagein altering the concentration of PHEMAs was also investigated. Urine samples were collected at the beginning and at the end of the workshift from 10 workers exposed to different levels of styrene. Each sample was analysed both by LC/MS/MS after storage under different conditions (respectively, at −20 and +4 ◦C, and after repeated freezing–thawing cycles), and by HPLC-FLD (in thesame conditions of storage). Strong correlations were found between the two methods both for total PHEMAs and for each of the isomers measured, including the minor (S,R)-M1. Also an alternative approach, the Bland–Altman test, confirmed the agreement between the two methods. The different storage conditions tested did not decrease the concentration of PHEMAs but, surprisingly, a clear trend to increase was shown, particularly for (R,R)-M1, (S,R)-M2 and (R,R)-M2 in samples stored at +4 ◦C for 1 week. In conclusion, the study demonstrates that the methods give comparable results. Indirectly, this confirms also the main characteristics of PHEMAs, showed in the previous experiments: lowbiotransformation rates of styrene into PHEMAs; large inter-individual variability; and the presence of a clear preference in the excretion of the isomers deriving from (S)-styrene oxide. PHEMAs appear stable under different storage conditions, but further studies are needed to explain the increase of levels that occurs when samples are not kept frozen. To avoid pre-analytical errors, samples collected for biomonitoring or research purposes should be frozen as soon as possible, and thawed only one time just before the analysis.
2006
The Environmental Medicine & Public Health category includes resources concerned with hygiene and health, parasitic diseases and parasitology, tropical medicine, industrial medicine, occupational medicine, infection control, and preventive medicine. Also included are resources on environmental health (including aerosol) and cancer causes and control. Aviation and wilderness medicine journals are placed here as well.
Esperti anonimi
Inglese
Internazionale
STAMPA
162
2-3
257
259
3
STYRENE; MERCAPTURIC ACIDS; HPLC; MASS SPECTROMETRY; INTER-LAB CONTROL
6
info:eu-repo/semantics/article
262
Negri, S.; Maestri, L.; Andreoli, R.; Manini, P.; Mutti, A.; Imbriani, Marcello
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/111244
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 9
social impact