Objective Cortical grey matter lesions are common in multiple sclerosis (MS), but usually not seen on MRI. The authors compared the performance of double inversion recovery (DIR, currently considered the best available imaging sequence for detecting cortical lesions) with phase-sensitive inversion recovery (PSIR, a sequence allowing much higher resolution scans to be obtained in a clinically feasible time). Methods Sixty MS patients and 30 healthy controls underwent MRI scanning on a 3 Tesla scanner. The authors compared intracortical (IC) and leucocortical (LC) lesion counts obtained with a standard DIR sequence (13133 mm resolution, obtained in 4 min) and a PSIR sequence (0.5x0.5x2 mm, 11 min). Lesions were marked separately on DIR and PSIR scans. Results In the whole MS cohort, more cortical lesions were seen on the higher-resolution PSIR than the DIR scans (IC mean +/- SD: 18.1 +/- 9.8 vs 5.9 +/- 4.5, p<0.001; LC mean +/- SD: 13.4 +/- 12.9 vs 7.3 +/- 8.0, p<0.001). On PSIR, >= 1 IC lesion was seen in 60/60 MS patients and 1/30 controls, and >= 1 LC lesion in 60/60 patients and 6/30 controls. On DIR, >= 1 IC lesion was seen in 50/60 patients and 0/30 controls, and >= 1 LC lesion(s) in 60/60 patients and 5/30 controls. Conclusions Compared with DIR, using PSIR the authors are able to detect a significantly greater number of cortical grey matter lesions. The presence of at least one IC lesion in every MS patient, but very few healthy controls, suggests that it may be a useful adjunct to conventional MRI when a diagnosis of MS is suspected but not confirmed

Improved detection of cortical MS lesions with phase-sensitive inversion recovery MRI

GANDINI, CLAUDIA;
2012-01-01

Abstract

Objective Cortical grey matter lesions are common in multiple sclerosis (MS), but usually not seen on MRI. The authors compared the performance of double inversion recovery (DIR, currently considered the best available imaging sequence for detecting cortical lesions) with phase-sensitive inversion recovery (PSIR, a sequence allowing much higher resolution scans to be obtained in a clinically feasible time). Methods Sixty MS patients and 30 healthy controls underwent MRI scanning on a 3 Tesla scanner. The authors compared intracortical (IC) and leucocortical (LC) lesion counts obtained with a standard DIR sequence (13133 mm resolution, obtained in 4 min) and a PSIR sequence (0.5x0.5x2 mm, 11 min). Lesions were marked separately on DIR and PSIR scans. Results In the whole MS cohort, more cortical lesions were seen on the higher-resolution PSIR than the DIR scans (IC mean +/- SD: 18.1 +/- 9.8 vs 5.9 +/- 4.5, p<0.001; LC mean +/- SD: 13.4 +/- 12.9 vs 7.3 +/- 8.0, p<0.001). On PSIR, >= 1 IC lesion was seen in 60/60 MS patients and 1/30 controls, and >= 1 LC lesion in 60/60 patients and 6/30 controls. On DIR, >= 1 IC lesion was seen in 50/60 patients and 0/30 controls, and >= 1 LC lesion(s) in 60/60 patients and 5/30 controls. Conclusions Compared with DIR, using PSIR the authors are able to detect a significantly greater number of cortical grey matter lesions. The presence of at least one IC lesion in every MS patient, but very few healthy controls, suggests that it may be a useful adjunct to conventional MRI when a diagnosis of MS is suspected but not confirmed
2012
Medical Research, Diagnosis & Treatment contains studies of existing and developing diagnostic and therapeutic techniques, as well as specific classes of clinical intervention. Resources in this category emphasize the difference between normal and disease states, with the ultimate goal of more effective diagnosis and intervention. Specific areas of interest include pathology and histochemical analysis of tissue, clinical chemistry and biochemical analysis of medical samples, diagnostic imaging, radiology and radiation, surgical research, anesthesiology and anesthesia, transplantation, artificial tissues, and medical implants. Resources focused on the disease, diagnosis, and treatment of specific organs or physiological systems are excluded and are covered in the Medical Research: Organs & Systems category.
Esperti anonimi
Inglese
Internazionale
STAMPA
83
9
877
882
6
MULTIPLE-SCLEROSIS PATIENTS, VIRCHOW-ROBIN SPACES, INTRACORTICAL LESIONS, COGNITIVE IMPAIRMENT, GRAY-MATTER, DEMYELINATION, PATHOLOGY, DISABILITY, CONTRAST, TESLA
8
info:eu-repo/semantics/article
262
Sethi, V; Yousry, Ta; Muhlert, N; Ron, M; Golay, X; Gandini, Claudia; Miller, Dh; Chard, Dt
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1112635
Citazioni
  • ???jsp.display-item.citation.pmc??? 80
  • Scopus 143
  • ???jsp.display-item.citation.isi??? 135
social impact