Fourteen titanium dental implants (Tioblast™) were implanted singly in the proximal tibia of New Zealand rabbits for 120 days. A bone defect was surgically produced and filled with Bio-Oss® around six of these implants. After the animals were sacrificed and their organs harvested, bone segments were fixed and methacrylate embedded after the push-in test had been performed. Microradiography was performed on longitudinal sections of the implants, whereas scanning electron microscope analysis was performed on the remaining embedded half-implants using secondary electrons only. The results showed that the implants were apically and coronally surrounded by bone, whether Bio-Oss® was used or not. Fractures were evident through the newly formed bone and between the pre-existing and newly formed bone. Some fracture lines propagated through the bone and stopped at the implant surface without continuing along the bone-titanium interface. Detachment between the implant and the bone occurred at the coronal extremity of the implants and along its cervical region. These results highlight the fact that the bone-titanium interface has a high resistance to loading. It exhibited greater resistance than the newly formed bone and seems to behave in a manner similar to the cement lines of osteons.

Behavior of the bone-titanium interface after push-in testing: a morphological study.

RODRIGUEZ Y BAENA, RUGGERO;RIZZO, SILVANA;BRUSOTTI, CESARE;
2003-01-01

Abstract

Fourteen titanium dental implants (Tioblast™) were implanted singly in the proximal tibia of New Zealand rabbits for 120 days. A bone defect was surgically produced and filled with Bio-Oss® around six of these implants. After the animals were sacrificed and their organs harvested, bone segments were fixed and methacrylate embedded after the push-in test had been performed. Microradiography was performed on longitudinal sections of the implants, whereas scanning electron microscope analysis was performed on the remaining embedded half-implants using secondary electrons only. The results showed that the implants were apically and coronally surrounded by bone, whether Bio-Oss® was used or not. Fractures were evident through the newly formed bone and between the pre-existing and newly formed bone. Some fracture lines propagated through the bone and stopped at the implant surface without continuing along the bone-titanium interface. Detachment between the implant and the bone occurred at the coronal extremity of the implants and along its cervical region. These results highlight the fact that the bone-titanium interface has a high resistance to loading. It exhibited greater resistance than the newly formed bone and seems to behave in a manner similar to the cement lines of osteons.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/114668
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact