Aim: In the last two decades, results of endovascular aortic repair (EVAR) for the treatment of infrarenal abdominal aortic aneurysms (AAAs) have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary reinterventions. We present our initial experience with the Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain), a new-generation trimodular endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. Methods: We treated 8 patients with anatomically suitable non-ruptured AAA. Results: Primary technical success was obtained in all patients, and no 30-day device-related complications nor deaths were reported. One patient experienced graft limb occlusion at 3 months, and underwent surgical conversion. At 1-year follow-up (completed in 6 patients), no device-related complications nor type I or III endoleak were observed. Conclusion: Initial personal experience with the Treovance abdominal stent-graft was satisfactory with regard to technical success and short-term clinical results. This new-generation endovascular device performed well even in angulated or heavily calcified anatomies.

The Bolton Treovance endograft: Single center experience

MARONE, ENRICO MARIA;
2014-01-01

Abstract

Aim: In the last two decades, results of endovascular aortic repair (EVAR) for the treatment of infrarenal abdominal aortic aneurysms (AAAs) have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary reinterventions. We present our initial experience with the Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain), a new-generation trimodular endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. Methods: We treated 8 patients with anatomically suitable non-ruptured AAA. Results: Primary technical success was obtained in all patients, and no 30-day device-related complications nor deaths were reported. One patient experienced graft limb occlusion at 3 months, and underwent surgical conversion. At 1-year follow-up (completed in 6 patients), no device-related complications nor type I or III endoleak were observed. Conclusion: Initial personal experience with the Treovance abdominal stent-graft was satisfactory with regard to technical success and short-term clinical results. This new-generation endovascular device performed well even in angulated or heavily calcified anatomies.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1149982
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact