BACKGROUND: Esophageal pressure (Pes) can provide information to guide mechanical ventilation in acute respiratory failure. However, both relative changes and absolute values of Pes can be affected by inappropriate filling of the esophageal balloon and by the elastance of the esophagus wall. We evaluated the feasibility and effectiveness of a calibration procedure consisting in optimization of balloon filling and subtraction of the pressure generated by the esophagus wall (Pew). METHODS: An esophageal balloon was progressively filled in 36 patients under controlled mechanical ventilation. VBEST was the filling volume associated with the largest tidal increase of Pes. Esophageal wall elastance was quantified and Pew was computed at each filling volume. Different filling strategies were compared by performing a validation occlusion test. RESULTS: Fifty series of measurements were performed. VBEST was 3.5 ± 1.9 ml (range 0.5-6.0). Esophagus elastance was 1.1 ± 0.5 cmH2O/ml (0.3-3.1). Both Pew and the result of the occlusion test differed among filling strategies. At filling volumes of 0.5, VBEST and 4.0 ml respectively, Pew was 0.0 ± 0.1, 2.0 ± 1.9, and 3.0 ± 1.7 cmH2O (p < 0.0001), whereas the occlusion test was satisfactory in 22%, 98%, and 88% of cases (p < 0.0001). CONCLUSIONS: Under mechanical ventilation, an increase of balloon filling above the conventionally recommended low volumes warrants complete transmission of Pes swings, but is associated with significant elevation of baseline. A simple calibration procedure allows finding the filling volume associated with the best transmission of tidal Pes change and subtracting the associated baseline artifact, thus making measurement of absolute values of Pes reliable.

In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable

MOJOLI, FRANCESCO;IOTTI, GIORGIO ANTONIO;BRASCHI, ANTONIO;
2016-01-01

Abstract

BACKGROUND: Esophageal pressure (Pes) can provide information to guide mechanical ventilation in acute respiratory failure. However, both relative changes and absolute values of Pes can be affected by inappropriate filling of the esophageal balloon and by the elastance of the esophagus wall. We evaluated the feasibility and effectiveness of a calibration procedure consisting in optimization of balloon filling and subtraction of the pressure generated by the esophagus wall (Pew). METHODS: An esophageal balloon was progressively filled in 36 patients under controlled mechanical ventilation. VBEST was the filling volume associated with the largest tidal increase of Pes. Esophageal wall elastance was quantified and Pew was computed at each filling volume. Different filling strategies were compared by performing a validation occlusion test. RESULTS: Fifty series of measurements were performed. VBEST was 3.5 ± 1.9 ml (range 0.5-6.0). Esophagus elastance was 1.1 ± 0.5 cmH2O/ml (0.3-3.1). Both Pew and the result of the occlusion test differed among filling strategies. At filling volumes of 0.5, VBEST and 4.0 ml respectively, Pew was 0.0 ± 0.1, 2.0 ± 1.9, and 3.0 ± 1.7 cmH2O (p < 0.0001), whereas the occlusion test was satisfactory in 22%, 98%, and 88% of cases (p < 0.0001). CONCLUSIONS: Under mechanical ventilation, an increase of balloon filling above the conventionally recommended low volumes warrants complete transmission of Pes swings, but is associated with significant elevation of baseline. A simple calibration procedure allows finding the filling volume associated with the best transmission of tidal Pes change and subtracting the associated baseline artifact, thus making measurement of absolute values of Pes reliable.
2016
The Anesthesia & Intensive Care category covers resources concerned with all aspects of anesthesia including the delivery and administration of anesthetics, emergency medicine, critical care medicine, traumatology, burns, injury, and resuscitation.
Esperti anonimi
Inglese
Internazionale
20
1
98
Calibration; Esophageal artifact; Esophageal balloon catheter; Esophageal elastance; Esophageal pressure; Mechanical ventilation; Pleural pressure; Protective ventilation; Transpulmonary pressure; Ventilator-induced lung injury; Calibration; Esophagus; Humans; Monitoring, Physiologic; Positive-Pressure Respiration; Respiration, Artificial; Respiratory Mechanics; Pressure; Critical Care and Intensive Care Medicine
http://ccforum.com/content/17
8
info:eu-repo/semantics/article
262
Mojoli, Francesco; Iotti, GIORGIO ANTONIO; Torriglia, Francesca; Pozzi, Marco; Volta, Carlo Alberto; Bianzina, Stefania; Braschi, Antonio; Brochard, L...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1165444
Citazioni
  • ???jsp.display-item.citation.pmc??? 62
  • Scopus 104
  • ???jsp.display-item.citation.isi??? 103
social impact