The objective of this study was to assess immediate and midterm outcomes for urgent/emergent and elective patients with thoracoabdominal aortic aneurysms (TAAAs) treated with the first commercially available "off-the-shelf" multibranched endograft for endovascular aneurysm repair, with a single-step or a staged surgical approach. METHODS: A multicenter, nonrandomized, retrospective study was conducted of TAAA patients grouped by urgent/emergent and elective treatment with multibranched endograft for endovascular aneurysm repair at 13 Italian centers from November 2012 to August 2016. Urgent/emergent repair was classified as rupture in 16%, impending rupture in 9%, pain in 53%, or a maximum TAAA diameter ≥80 mm in 22%. Study end points were technical success, mortality, spinal cord ischemia, target visceral vessel (TVV) patency, and procedure-related reinterventions at 30 days and at follow-up. RESULTS: Seventy-three patients (274 TVVs) were enrolled. Treatment was performed in elective (n = 41 [56%]) or urgent/emergent (n = 32 [44%]) settings, according to a single-step (n = 30 [41%]) or staged (n = 43 [59%]) approach. Technical success was 92%. Mortality within 30 days was 4% (n = 3 urgent/emergent patients) due to myocardial infarction. Spinal cord ischemia was recorded in two patients (3%; elective group). The primary patency of TVVs was 99% (three renal branch occlusions). Procedure-related reinterventions were required in five cases (7%). At least one adverse event from any cause ≤30 days was registered in 42% (n = 31). At a median follow-up of 18 months (range, 1-43 months), eight (11%) deaths (elective vs urgent/emergent, 2% vs 22%; P = .018), three (1%) cases of branch occlusion or stenosis, and five (7%) reinterventions were recorded. A survival of 88% (standard error [SE], 4%), 86% (SE, 4%), and 82% (SE, 5%) was evidenced at 12, 24, and 36 months, respectively. Urgent/emergent repair and female gender were identified as independent risk factors for all-cause mortality (P < .001 and P = .015, respectively), and the staged approach was identified as protective (P = .026). Freedom from reintervention was 86% (SE, 4%) and 83% (SE, 5%) at 12 and 24 months. CONCLUSIONS: The first off-the-shelf multibranched endograft seems safe in both urgent/emergent and elective settings. The staged surgical approach appears to positively influence overall survival. This unique device and its operators will usher in a new treatment paradigm for TAAA repair.

Standard "off-the-shelf" multibranched thoracoabdominal endograft in urgent and elective patients with single and staged procedures in a multicenter experience

Marone, Enrico Maria;
2018-01-01

Abstract

The objective of this study was to assess immediate and midterm outcomes for urgent/emergent and elective patients with thoracoabdominal aortic aneurysms (TAAAs) treated with the first commercially available "off-the-shelf" multibranched endograft for endovascular aneurysm repair, with a single-step or a staged surgical approach. METHODS: A multicenter, nonrandomized, retrospective study was conducted of TAAA patients grouped by urgent/emergent and elective treatment with multibranched endograft for endovascular aneurysm repair at 13 Italian centers from November 2012 to August 2016. Urgent/emergent repair was classified as rupture in 16%, impending rupture in 9%, pain in 53%, or a maximum TAAA diameter ≥80 mm in 22%. Study end points were technical success, mortality, spinal cord ischemia, target visceral vessel (TVV) patency, and procedure-related reinterventions at 30 days and at follow-up. RESULTS: Seventy-three patients (274 TVVs) were enrolled. Treatment was performed in elective (n = 41 [56%]) or urgent/emergent (n = 32 [44%]) settings, according to a single-step (n = 30 [41%]) or staged (n = 43 [59%]) approach. Technical success was 92%. Mortality within 30 days was 4% (n = 3 urgent/emergent patients) due to myocardial infarction. Spinal cord ischemia was recorded in two patients (3%; elective group). The primary patency of TVVs was 99% (three renal branch occlusions). Procedure-related reinterventions were required in five cases (7%). At least one adverse event from any cause ≤30 days was registered in 42% (n = 31). At a median follow-up of 18 months (range, 1-43 months), eight (11%) deaths (elective vs urgent/emergent, 2% vs 22%; P = .018), three (1%) cases of branch occlusion or stenosis, and five (7%) reinterventions were recorded. A survival of 88% (standard error [SE], 4%), 86% (SE, 4%), and 82% (SE, 5%) was evidenced at 12, 24, and 36 months, respectively. Urgent/emergent repair and female gender were identified as independent risk factors for all-cause mortality (P < .001 and P = .015, respectively), and the staged approach was identified as protective (P = .026). Freedom from reintervention was 86% (SE, 4%) and 83% (SE, 5%) at 12 and 24 months. CONCLUSIONS: The first off-the-shelf multibranched endograft seems safe in both urgent/emergent and elective settings. The staged surgical approach appears to positively influence overall survival. This unique device and its operators will usher in a new treatment paradigm for TAAA repair.
2018
Medical Research, Diagnosis & Treatment contains studies of existing and developing diagnostic and therapeutic techniques, as well as specific classes of clinical intervention. Resources in this category emphasize the difference between normal and disease states, with the ultimate goal of more effective diagnosis and intervention. Specific areas of interest include pathology and histochemical analysis of tissue, clinical chemistry and biochemical analysis of medical samples, diagnostic imaging, radiology and radiation, surgical research, anesthesiology and anesthesia, transplantation, artificial tissues, and medical implants. Resources focused on the disease, diagnosis, and treatment of specific organs or physiological systems are excluded and are covered in the Medical Research: Organs & Systems category.
Inglese
Internazionale
STAMPA
67
4
1005
1016
12
18
info:eu-repo/semantics/article
262
Silingardi, Roberto; Gennai, Stefano; Leone, Nicola; Gargiulo, Mauro; Faggioli, Gianluca; Cao, Piergiorgio; Verzini, Fabio; Ippoliti, Arnaldo; Tusini,...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1204227
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 65
social impact