The aim of this work is to study the effects of eccentric hypertrophy on the electromechanics of a single myocardial ventricular fiber by means of a one-dimensional finite-element strongly-coupled model. The electrical current flow model is written in the reference configuration and it is characterized by two geometric feedbacks, i.e. the conduction and convection ones, and by the mechanoelectric feedback due to stretch-activated channels. First, the influence of such feedbacks is investigated for both a healthy and a hypertrophic fiber in case of isometric simulations. No relevant discrepancies are found when disregarding one or more feedbacks for both fibers. Then, all feedbacks are taken into account while studying the electromechanical responses of fibers. The results from isometric tests do not point out any notable difference between the healthy and hypertrophic fibers as regards the action potential duration and conduction velocity. The length-tension relationships show increased stretches and reduced peak values for tension instead. The tension-velocity relationships derived from afterloaded isotonic and quick-release tests depict higher values of contraction velocity at smaller afterloads. Moreover, higher maximum shortenings are achieved during the isotonic contraction. In conclusion, our simulation results are innovative in predicting the electromechanical behavior of eccentric hypertrophic fibers.

Computational modeling of the electromechanical response of a ventricular fiber affected by eccentric hypertrophy

Del Bianco F;Colli Franzone P;Fassina L.
2017-01-01

Abstract

The aim of this work is to study the effects of eccentric hypertrophy on the electromechanics of a single myocardial ventricular fiber by means of a one-dimensional finite-element strongly-coupled model. The electrical current flow model is written in the reference configuration and it is characterized by two geometric feedbacks, i.e. the conduction and convection ones, and by the mechanoelectric feedback due to stretch-activated channels. First, the influence of such feedbacks is investigated for both a healthy and a hypertrophic fiber in case of isometric simulations. No relevant discrepancies are found when disregarding one or more feedbacks for both fibers. Then, all feedbacks are taken into account while studying the electromechanical responses of fibers. The results from isometric tests do not point out any notable difference between the healthy and hypertrophic fibers as regards the action potential duration and conduction velocity. The length-tension relationships show increased stretches and reduced peak values for tension instead. The tension-velocity relationships derived from afterloaded isotonic and quick-release tests depict higher values of contraction velocity at smaller afterloads. Moreover, higher maximum shortenings are achieved during the isotonic contraction. In conclusion, our simulation results are innovative in predicting the electromechanical behavior of eccentric hypertrophic fibers.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1208509
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0