This paper presents the results of a unidirectional shake-table test performed on a full-scale, single-storey unreinforced masonry building. The specimen represented a typical detached house of the Groningen region of the Netherlands, consisting of double-wythe clay-brick unreinforced masonry walls, without any specific seismic detailing. The building prototype included large openings and a reentrant corner, causing a discontinuity in one of the perimeter walls. The floor was made of timber beams and planks, resulting in a flexible diaphragm. The roof, characterized by a very steep pitch, consisted of a series of timber trusses connected by wood purlins and boards. The two façades perpendicular to the shaking direction were designed to represent two typical gable geometries. An incremental dynamic test was conducted up to the near-collapse state of the specimen, using input ground motions compatible with induced-seismicity scenarios for the examined region. This paper summarizes the main characteristics of the specimen and the shake-table experimental results, illustrating the dynamic response of the structure, the evolution of the damage mechanisms, and the attainment of significant limit states.

Experimental seismic performance of a full-scale unreinforced clay-masonry building with flexible timber diaphragms

Stylianos Kallioras;Gabriele Guerrini;Umberto Tomassetti;MARCHESI, BEATRICE;Andrea Penna;Francesco Graziotti;Guido Magenes
2018-01-01

Abstract

This paper presents the results of a unidirectional shake-table test performed on a full-scale, single-storey unreinforced masonry building. The specimen represented a typical detached house of the Groningen region of the Netherlands, consisting of double-wythe clay-brick unreinforced masonry walls, without any specific seismic detailing. The building prototype included large openings and a reentrant corner, causing a discontinuity in one of the perimeter walls. The floor was made of timber beams and planks, resulting in a flexible diaphragm. The roof, characterized by a very steep pitch, consisted of a series of timber trusses connected by wood purlins and boards. The two façades perpendicular to the shaking direction were designed to represent two typical gable geometries. An incremental dynamic test was conducted up to the near-collapse state of the specimen, using input ground motions compatible with induced-seismicity scenarios for the examined region. This paper summarizes the main characteristics of the specimen and the shake-table experimental results, illustrating the dynamic response of the structure, the evolution of the damage mechanisms, and the attainment of significant limit states.
2018
Civil Engineering covers engineering-based resources in the subfields of structural engineering, geotechnics, earthquake engineering, ocean engineering, water resources and supply, naval engineering, marine engineering, transportation engineering, and municipal engineering. Topics covered include the planning, design, construction, and maintenance of fixed structures and ground facilities for industry, occupancy, transportation, use and control of water, and harbor facilities.
Esperti anonimi
Inglese
Internazionale
STAMPA
161
231
249
19
Unreinforced masonry (URM) building, Full-scale shake-table test, Seismic performance, Solid clay brick, Flexible diaphragm, Induced seismicity
https://www.sciencedirect.com/science/article/pii/S0141029617337094
no
7
info:eu-repo/semantics/article
262
Kallioras, Stylianos; Guerrini, Gabriele; Tomassetti, Umberto; Marchesi, Beatrice; Penna, Andrea; Graziotti, Francesco; Magenes, Guido
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1212452
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 57
social impact