The MEG II experiment is designed to improve by an order of magnitude the sensitivity of 4.2 x 10(-13) reached by MEG on the search for mu(+) -> e(+) gamma decay. A pixelated Timing Counter (pTC) has been developed to improve the time resolution by measuring the positron time information independently with several counters. We constructed and installed the pTC and performed commissioning runs at the pi E5 beam line at PSI. A resolution of 38.5 ps is obtained with commissioning run data.

Development and commissioning of the 30 ps time resolution MEG II pixelated Timing Detector

Boca G.;De Bari A.;
2019-01-01

Abstract

The MEG II experiment is designed to improve by an order of magnitude the sensitivity of 4.2 x 10(-13) reached by MEG on the search for mu(+) -> e(+) gamma decay. A pixelated Timing Counter (pTC) has been developed to improve the time resolution by measuring the positron time information independently with several counters. We constructed and installed the pTC and performed commissioning runs at the pi E5 beam line at PSI. A resolution of 38.5 ps is obtained with commissioning run data.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1282229
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact