Carbon ion therapy is an advanced radiation treatment modality considering its distinct dose distribution and high biological effectiveness. However, carbon ion therapy has become more sensitive to the range uncertainty comparing to the traditional x-ray radiotherapy because of its steep dose distribution near the Bragg peak, which makes the benefits not been fully utilized. Prompt gamma (PG) spectroscopy is one of the potential choices to achieve the range verification in carbon ion therapy. In this paper, we describe that the Doppler shift effect causes the energy shift of PG (4.44 MeV) produced by the de-excitation of the flying 12C*, which makes PG spectroscopy an alternative method for range verification. In order to prove its feasibility of applying this method during patient treatment, Monte Carlo simulation and analytical calculation are compared to verify the accuracy with different materials and non-uniform geometry model. The proposed method is applied to range measurement in the homogeneous phantom filled with different materials (polyethylene, water, and adipose) and the Chinese hybrid radiation phantom with two different irradiated positions (chest and abdomen). Results show that the difference value is less than 2.1% for three homogeneous phantoms. Moreover, good conformance is obtained when using the Chinese hybrid radiation phantom in both irradiated positions. These results prove the feasibility of using the proposed method in a more complicated heterogeneous human model.

Evaluation of using the Doppler shift effect of prompt gamma for measuring the carbon ion range in vivo for heterogeneous phantoms

Shu D.;Altieri S.
2020-01-01

Abstract

Carbon ion therapy is an advanced radiation treatment modality considering its distinct dose distribution and high biological effectiveness. However, carbon ion therapy has become more sensitive to the range uncertainty comparing to the traditional x-ray radiotherapy because of its steep dose distribution near the Bragg peak, which makes the benefits not been fully utilized. Prompt gamma (PG) spectroscopy is one of the potential choices to achieve the range verification in carbon ion therapy. In this paper, we describe that the Doppler shift effect causes the energy shift of PG (4.44 MeV) produced by the de-excitation of the flying 12C*, which makes PG spectroscopy an alternative method for range verification. In order to prove its feasibility of applying this method during patient treatment, Monte Carlo simulation and analytical calculation are compared to verify the accuracy with different materials and non-uniform geometry model. The proposed method is applied to range measurement in the homogeneous phantom filled with different materials (polyethylene, water, and adipose) and the Chinese hybrid radiation phantom with two different irradiated positions (chest and abdomen). Results show that the difference value is less than 2.1% for three homogeneous phantoms. Moreover, good conformance is obtained when using the Chinese hybrid radiation phantom in both irradiated positions. These results prove the feasibility of using the proposed method in a more complicated heterogeneous human model.
2020
The Physics category includes resources of a broad, general nature that contain materials from all areas of physics, The category also includes resources specifically concerned with the following physics sub-fields: mathematical physics, particle and nuclear physics, physics of fluids and plasmas, quantum physics, and theoretical physics.
Esperti anonimi
Inglese
Internazionale
STAMPA
959
163439
7
Carbon ion therapy; Doppler shift effect; Prompt gamma spectroscopy; Range verify cation
http://www.sciencedirect.com/science/journal/01689002
6
info:eu-repo/semantics/article
262
Geng, C.; Han, Y.; Tang, X.; Shu, D.; Gong, C.; Altieri, S.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1320590
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact