Background: A reliable early marker is required for diagnosis of cobalamin deficiency. We calculated an appropriate holotranscobalamin (HoloTC) cut-off point for identifying cobalamin deficiency using an immunoenzymatic assay. Methods: Determination of the cut-off threshold and correlation between HoloTC and the other diagnostic parameters routinely used for vitamin B12 deficiency [total vitamin B12 (tB12), folate, homocysteine] were measured in 250 routine blood specimens from 107 men (mean age 59.0±18.8 years) and 143 women (mean age 54.2±23.1 years). The inclusion criterion was serum tB12 concentration ≤221 pmol/L. Results: Analytical performance results agreed with those reported by others. A weak correlation (R=0.42) was found between HoloTC and tB12. A 40 pmol/L cut-off threshold was chosen for HoloTC and the associated sensitivity and specificity was 0.86 and 0.66, respectively. Out of 250 tested samples, 126 showed tB12 concentrations 139-221 pmol/L (gray zone, GZ) and 124 had tB12 concentrations <139 pmol/L (low, L). Values less than the cut-off for HoloTC were present in 68.2% and 37.9% of cases in the GZ and L group, respectively (p<0.01), and in 53.2% of subjects. Conclusions: Our results confirmed the analytical reliability of the AxSYM HoloTC assay. The method is adequate for routine use and a cut-off threshold of 40 pmol/L is appropriate for assessing cobalamin deficiency in populations with reduced tB12 values. © 2010 by Walter de Gruyter Berlin New York.
Determination of serum holotranscobalamin concentrations with the AxSYM active B12 assay: Cut-off point evaluation in the clinical laboratory
De Giuseppe R.;
2010-01-01
Abstract
Background: A reliable early marker is required for diagnosis of cobalamin deficiency. We calculated an appropriate holotranscobalamin (HoloTC) cut-off point for identifying cobalamin deficiency using an immunoenzymatic assay. Methods: Determination of the cut-off threshold and correlation between HoloTC and the other diagnostic parameters routinely used for vitamin B12 deficiency [total vitamin B12 (tB12), folate, homocysteine] were measured in 250 routine blood specimens from 107 men (mean age 59.0±18.8 years) and 143 women (mean age 54.2±23.1 years). The inclusion criterion was serum tB12 concentration ≤221 pmol/L. Results: Analytical performance results agreed with those reported by others. A weak correlation (R=0.42) was found between HoloTC and tB12. A 40 pmol/L cut-off threshold was chosen for HoloTC and the associated sensitivity and specificity was 0.86 and 0.66, respectively. Out of 250 tested samples, 126 showed tB12 concentrations 139-221 pmol/L (gray zone, GZ) and 124 had tB12 concentrations <139 pmol/L (low, L). Values less than the cut-off for HoloTC were present in 68.2% and 37.9% of cases in the GZ and L group, respectively (p<0.01), and in 53.2% of subjects. Conclusions: Our results confirmed the analytical reliability of the AxSYM HoloTC assay. The method is adequate for routine use and a cut-off threshold of 40 pmol/L is appropriate for assessing cobalamin deficiency in populations with reduced tB12 values. © 2010 by Walter de Gruyter Berlin New York.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.