The development and characterization of an anti-aflatoxin B1 (anti-AFB1) immunoaffinity monolithic disk is reported. Polyclonal anti-AFB1 was covalently immobilized in batch on an epoxy-activated monolithic Convective Interaction Media (CIM) disk (12mm×3mmi.d.) by a one-step reaction via epoxy groups of the polymer surface. 0.96 mgof antibody were immobilized and the binding capacity of the CIM diskwas determined by frontal analysis. The CIM diskwas coupled through a switching valve to a reversed-phase column, namely Chromolith Performance RP-18e.Afully automated HPLC method with fluorescence detection for the determination of aflatoxin B1 in aqueous solution was developed. The total analysis time with the integrated system is 46 min and the retention time of AFB1 is approximately 29 min. The binding capacity of the immunoaffinity disk was evaluated in terms of linearity, precision and accuracy of the extraction procedure. The immunoaffinity support was stable after repeated runs.

Development and integration of an immunoaffinity monolithic disk for the on-line solid-phase extraction and HPLC determination with fluorescence detection of aflatoxin B1 in aqueous solutions

CALLERI, ENRICA;MARRUBINI BOULAND, GIORGIO CARLO;BRUSOTTI, GLORIA;MASSOLINI, GABRIELLA;CACCIALANZA, GABRIELE
2007-01-01

Abstract

The development and characterization of an anti-aflatoxin B1 (anti-AFB1) immunoaffinity monolithic disk is reported. Polyclonal anti-AFB1 was covalently immobilized in batch on an epoxy-activated monolithic Convective Interaction Media (CIM) disk (12mm×3mmi.d.) by a one-step reaction via epoxy groups of the polymer surface. 0.96 mgof antibody were immobilized and the binding capacity of the CIM diskwas determined by frontal analysis. The CIM diskwas coupled through a switching valve to a reversed-phase column, namely Chromolith Performance RP-18e.Afully automated HPLC method with fluorescence detection for the determination of aflatoxin B1 in aqueous solution was developed. The total analysis time with the integrated system is 46 min and the retention time of AFB1 is approximately 29 min. The binding capacity of the immunoaffinity disk was evaluated in terms of linearity, precision and accuracy of the extraction procedure. The immunoaffinity support was stable after repeated runs.
2007
Chemistry & Analysis covers research on natural and laboratory syntheses, chemical structure, structure-function relationship, isolation and analyses of biologically significant molecules, medicinal and food chemistry. Technical material describing crucial chemical methods in biochemical analysis and research is also placed in this category. Resources covering general biochemistry and natural metabolic pathways are excluded.
Sì, ma tipo non specificato
Inglese
Internazionale
ELETTRONICO
44
396
403
8
Tematica Ex SIR: Ricerche in ambito chimico tossicologico e ambientale (Classif. Ex SIR:Articoli su riviste ISI )
immunoaffinity disk; aflatoxin B1; immunoextraction
5
info:eu-repo/semantics/article
262
Calleri, Enrica; MARRUBINI BOULAND, GIORGIO CARLO; Brusotti, Gloria; Massolini, Gabriella; Caccialanza, Gabriele
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/134425
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 56
social impact