Benzene is a highly toxic aromatic hydrocarbon. Inhaling benzene can cause dizziness, vertigo, headaches, aplasia, mutations and, in the most extreme cases, cancer. Trans,trans-muconic acid (t,t-MA) is one of the metabolization products of benzene. Although different analytical methods have been reported for the determination of t,t-MA, these are often expensive, require trained personnel, are not suitable for on-site measurements, and use hazardous organic solvents. For these reasons, the development of reliable, selective and sensitive methods for rapid and in situ detection of t,t-MA are of importance. Addressing this challenge, a nanodevice for the selective and sensitive quantification of t,t-MA in urine is reported. The nanodevice used is achieved using mesoporous silica nanoparticles loaded with a dye reporter and capped with a dicopper(II) azacryptand. Pore opening and payload release is induced rapidly (10 min) and selectively with t,t-MA in urine, using a simple fluorimeter without sample pretreatment.

A Nanoprobe Based on Gated Mesoporous Silica Nanoparticles for The Selective and Sensitive Detection of Benzene Metabolite t,t-Muconic Acid in Urine

Licchelli M.
;
Mangano C.;Amendola V.;
2021-01-01

Abstract

Benzene is a highly toxic aromatic hydrocarbon. Inhaling benzene can cause dizziness, vertigo, headaches, aplasia, mutations and, in the most extreme cases, cancer. Trans,trans-muconic acid (t,t-MA) is one of the metabolization products of benzene. Although different analytical methods have been reported for the determination of t,t-MA, these are often expensive, require trained personnel, are not suitable for on-site measurements, and use hazardous organic solvents. For these reasons, the development of reliable, selective and sensitive methods for rapid and in situ detection of t,t-MA are of importance. Addressing this challenge, a nanodevice for the selective and sensitive quantification of t,t-MA in urine is reported. The nanodevice used is achieved using mesoporous silica nanoparticles loaded with a dye reporter and capped with a dicopper(II) azacryptand. Pore opening and payload release is induced rapidly (10 min) and selectively with t,t-MA in urine, using a simple fluorimeter without sample pretreatment.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1371041
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact