Objectives: Indications for and timing of pulmonary valve replacement (PVR) after tetralogy of Fallot repair are controversial. Among magnetic resonance imaging indices proposed to time valve replacement, a right ventricular (RV) end-diastolic volume index greater than 160 ml/m2 is often used. Recent evidence suggests that this value may still identify patients with irreversible RV dysfunction, thus hindering recovery. Our goal was to define, using intraoperative video kinematic evaluation, whether a relationship exists between timing of PVR and early functional recovery after surgery. Methods: Between November 2016 and November 2018, a total of 12 consecutive patients aged 27.1 ± 19.1 years underwent PVR on average 22.2 ± 13.3 years after tetralogy of Fallot repair. Mean RV end-diastolic volume evident on the magnetic resonance images was 136.9 ± 35.7 ml/m2. Intraoperative cardiac kinematics were assessed by video kinematic evaluation via a high-speed camera acquiring videos at 200 fps before and after valve replacement. Results: Patients presenting with RV end-diastolic volume <147 ml/m2 were significantly younger (11.2 ± 5.0 vs 38.4 ± 17.0; P = 0.005) and had a shorter time interval to valve replacement (11.0 ± 5.2 vs 30.1 ± 11.3; P = 0.03). The entire population showed a moderate correlation among energy expenditure, cardiac fatigue, perimeter of contraction and preoperative RV end-diastolic volume index. Both groups showed a reduction in all kinematic parameters after PVR, but those with end-diastolic volume >147 ml/m2 showed an unpredictable outcome. Conclusions: Video kinematic evaluation provides insight into intraoperative RV recovery in patients with tetralogy of Fallot undergoing PVR. Accordingly, functional recovery can be expected in patients with preoperative end-diastolic volume <147 ml/m2.

Right ventricular functional recovery depends on timing of pulmonary valve replacement in tetralogy of Fallot: a video kinematic study

Fassina L;
2021-01-01

Abstract

Objectives: Indications for and timing of pulmonary valve replacement (PVR) after tetralogy of Fallot repair are controversial. Among magnetic resonance imaging indices proposed to time valve replacement, a right ventricular (RV) end-diastolic volume index greater than 160 ml/m2 is often used. Recent evidence suggests that this value may still identify patients with irreversible RV dysfunction, thus hindering recovery. Our goal was to define, using intraoperative video kinematic evaluation, whether a relationship exists between timing of PVR and early functional recovery after surgery. Methods: Between November 2016 and November 2018, a total of 12 consecutive patients aged 27.1 ± 19.1 years underwent PVR on average 22.2 ± 13.3 years after tetralogy of Fallot repair. Mean RV end-diastolic volume evident on the magnetic resonance images was 136.9 ± 35.7 ml/m2. Intraoperative cardiac kinematics were assessed by video kinematic evaluation via a high-speed camera acquiring videos at 200 fps before and after valve replacement. Results: Patients presenting with RV end-diastolic volume <147 ml/m2 were significantly younger (11.2 ± 5.0 vs 38.4 ± 17.0; P = 0.005) and had a shorter time interval to valve replacement (11.0 ± 5.2 vs 30.1 ± 11.3; P = 0.03). The entire population showed a moderate correlation among energy expenditure, cardiac fatigue, perimeter of contraction and preoperative RV end-diastolic volume index. Both groups showed a reduction in all kinematic parameters after PVR, but those with end-diastolic volume >147 ml/m2 showed an unpredictable outcome. Conclusions: Video kinematic evaluation provides insight into intraoperative RV recovery in patients with tetralogy of Fallot undergoing PVR. Accordingly, functional recovery can be expected in patients with preoperative end-diastolic volume <147 ml/m2.
2021
Experimental Biology covers a wide array of topics concerned with research in general biology and biological systems, including evolution, ecology, radiation biology, anatomy, general biology, and resources containing diverse topics in basic biology research. Resources on general biomedicine are excluded and are covered in the Medical Research: General Topics category. Resources with strong reliance on fields that fall outside of the core topics of Life sciences, such as biomedical engineering are placed in the Multidisciplinary category.
Esperti anonimi
Inglese
Internazionale
STAMPA
59
6
1329
1336
8
Magnetic resonance imaging; Pulmonary valve replacement; Tetralogy of Fallot; Video kinematic evaluation
https://pubmed.ncbi.nlm.nih.gov/33547473/
no
10
info:eu-repo/semantics/article
262
Rozzi, G; Lo Muzio, Fp; Fassina, L; Rossi, S; Statello, R; Sandrini, C; Laricchiuta, M; Faggian, G; Miragoli, M; Luciani, Gb
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1387774
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact