PURPOSE: To compare the reliability of microkeratome dissection with the anterior chamber pressurizer (ACP) system versus conventional pressurization for ultrathin Descemet-stripping automated endothelial keratoplasty (UT-DSAEK) graft preparation.METHODS: A retrospective review of a consecutive series of dissected donor corneas processed at Pavia Eye Bank for UT-DSAEK surgery was performed. Grafts were prepared through single-pass microkeratome dissection with artificial anterior chamber internal pressure regulation through either ACP or the conventional method using a water column with tube clamp. The target central graft thickness (CGT) was ≤100 mum. Cutting predictability was determined as the difference between the microkeratome head size and the thickness actually removed. Graft regularity was investigated as central-to-peripheral thickness increase, central-to-peripheral (CP) ratio, and graft thickness uniformity. Thickness was measured with anterior segment optical coherence tomography (horizontal and vertical meridians).RESULTS: Of the 265 UT-DSAEK grafts, ACP achieved the target "CGT ≤ 100 mum" in 87 of 120 (72.5%), whereas the conventional technique achieved the same in 85 of 145 (58.6%) (P = 0.018). ACP predictability was -3.9 mum (SD: 2.3), whereas predictability of the conventional technique was -54.6 mum (SD: 3.7) (P < 0.001). Thickness increased similarly (P = 0.212); CP ratio was better with ACP for only 2 mm diameter (P = 0.001); graft thickness uniformity was comparable (P > 0.05).CONCLUSIONS: Compared with conventional pressurization, ACP improved microkeratome-assisted preparation reliability of UT-DSAEK grafts, achieving CGT ≤ 100 mum with significantly higher frequency (P = 0.018) and predictability (P < 0.001). ACP improved CP ratio only at 2 mm (P = 0.001); for other graft thickness, the 2 methods proved equivalent.

Single-Pass Mikrokeratome and Anterior Chamber Pressurizer for the Ultrathin Descemet-Stripping Automated Endothelial Keratoplasty Graft Preparation

Quaranta, Luciano
2021-01-01

Abstract

PURPOSE: To compare the reliability of microkeratome dissection with the anterior chamber pressurizer (ACP) system versus conventional pressurization for ultrathin Descemet-stripping automated endothelial keratoplasty (UT-DSAEK) graft preparation.METHODS: A retrospective review of a consecutive series of dissected donor corneas processed at Pavia Eye Bank for UT-DSAEK surgery was performed. Grafts were prepared through single-pass microkeratome dissection with artificial anterior chamber internal pressure regulation through either ACP or the conventional method using a water column with tube clamp. The target central graft thickness (CGT) was ≤100 mum. Cutting predictability was determined as the difference between the microkeratome head size and the thickness actually removed. Graft regularity was investigated as central-to-peripheral thickness increase, central-to-peripheral (CP) ratio, and graft thickness uniformity. Thickness was measured with anterior segment optical coherence tomography (horizontal and vertical meridians).RESULTS: Of the 265 UT-DSAEK grafts, ACP achieved the target "CGT ≤ 100 mum" in 87 of 120 (72.5%), whereas the conventional technique achieved the same in 85 of 145 (58.6%) (P = 0.018). ACP predictability was -3.9 mum (SD: 2.3), whereas predictability of the conventional technique was -54.6 mum (SD: 3.7) (P < 0.001). Thickness increased similarly (P = 0.212); CP ratio was better with ACP for only 2 mm diameter (P = 0.001); graft thickness uniformity was comparable (P > 0.05).CONCLUSIONS: Compared with conventional pressurization, ACP improved microkeratome-assisted preparation reliability of UT-DSAEK grafts, achieving CGT ≤ 100 mum with significantly higher frequency (P = 0.018) and predictability (P < 0.001). ACP improved CP ratio only at 2 mm (P = 0.001); for other graft thickness, the 2 methods proved equivalent.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1399754
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact