We report on the study of a new liquid scintillator target for neutrino interactions in the framework of the research and development program of the Borexino solar neutrino experiment. The scintillator consists of 1,2-dimethyl-4-(1-phenylethyl)-benzene (phenyl-o-xylylethane, PXE) as solvent and 1,4-diphenylbenzene (para-Terphenyl, p-Tp) as primary and 1,4-bis(2-methylstyryl)benzene (bis-MSB) as secondary solute. The density close to that of water and the high flash point makes it an attractive option for large scintillation detectors in general. The study focused on optical properties, radioactive trace impurities and novel purification techniques of the scintillator. Attenuation lengths of the scintillator mixture of 12 in at 430 nm were achieved after purification with an alumina column. A radiocarbon isotopic ratio of C-14/C-11 = 9.1 x 10(-18) has been measured in the scintillator. Initial trace impurities, e.g. U-238 at 3.2 x 10(-14) g/g could be purified to levels below 1 x 10(-17) g/g by silica gel solid column purification.

Study of phenylxylylethane (PXE) as scintillator for low energy neutrino experiments

DE BARI, ANTONIO;
2008-01-01

Abstract

We report on the study of a new liquid scintillator target for neutrino interactions in the framework of the research and development program of the Borexino solar neutrino experiment. The scintillator consists of 1,2-dimethyl-4-(1-phenylethyl)-benzene (phenyl-o-xylylethane, PXE) as solvent and 1,4-diphenylbenzene (para-Terphenyl, p-Tp) as primary and 1,4-bis(2-methylstyryl)benzene (bis-MSB) as secondary solute. The density close to that of water and the high flash point makes it an attractive option for large scintillation detectors in general. The study focused on optical properties, radioactive trace impurities and novel purification techniques of the scintillator. Attenuation lengths of the scintillator mixture of 12 in at 430 nm were achieved after purification with an alumina column. A radiocarbon isotopic ratio of C-14/C-11 = 9.1 x 10(-18) has been measured in the scintillator. Initial trace impurities, e.g. U-238 at 3.2 x 10(-14) g/g could be purified to levels below 1 x 10(-17) g/g by silica gel solid column purification.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/141872
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 34
social impact