In the coronavirus (CoV) disease 2019 (COVID-19) pandemic, highly selective serological testing is essential to define exposure to severe acute respiratory syndrome CoV 2 (SARS-CoV-2). Many tests have been developed, yet with variable speeds to first results, and are of unknown quality, particularly when considering the prediction of neutralizing capacity. The LIAISON SARS-CoV-2 S1/S2 IgG assay was designed to measure antibodies against the SARS-CoV-2 native S1/S2 proteins in a standardized automated chemiluminescence assay. The clinical and analytical performances of the test were validated in an observational study using residual samples (>1,500) with a positive or negative COVID-19 diagnosis. The LIAISON SARS-CoV-2 S1/S2 IgG assay proved to be highly selective and specific and offered semiquantitative measures of serum or plasma levels of anti-S1/S2 IgG with neutralizing activity. The assay's diagnostic sensitivities were 91.3% and 95.7% at ≥5 or >15 days from diagnosis, respectively, and 100% when assessed against a neutralizing assay. The assay's specificity ranged between 97% and 98.5%. The average imprecision of the assay was a >5% coefficient of variation. Assay performance at 2 different cutoffs was evaluated to optimize predictive values. The automated LIAISON SARS-CoV-2 S1/S2 IgG assay brings efficient, sensitive, specific, and precise serological testing to the laboratory, with the capacity to test large amounts of samples per day; first results are available within 35 min, with a throughput of 170 tests/hour. The semiquantitative results provided by the test also associate with the presence of neutralizing antibodies and may provide a useful tool for the large-scale screening of convalescent-phase plasma for safe therapeutic use.

Clinical and analytical performance of an automated serological test that identifies s1/s2-neutralizing igg in covid-19 patients semiquantitatively

Bonelli F.;Bonetti A.;Baldanti F.
2020-01-01

Abstract

In the coronavirus (CoV) disease 2019 (COVID-19) pandemic, highly selective serological testing is essential to define exposure to severe acute respiratory syndrome CoV 2 (SARS-CoV-2). Many tests have been developed, yet with variable speeds to first results, and are of unknown quality, particularly when considering the prediction of neutralizing capacity. The LIAISON SARS-CoV-2 S1/S2 IgG assay was designed to measure antibodies against the SARS-CoV-2 native S1/S2 proteins in a standardized automated chemiluminescence assay. The clinical and analytical performances of the test were validated in an observational study using residual samples (>1,500) with a positive or negative COVID-19 diagnosis. The LIAISON SARS-CoV-2 S1/S2 IgG assay proved to be highly selective and specific and offered semiquantitative measures of serum or plasma levels of anti-S1/S2 IgG with neutralizing activity. The assay's diagnostic sensitivities were 91.3% and 95.7% at ≥5 or >15 days from diagnosis, respectively, and 100% when assessed against a neutralizing assay. The assay's specificity ranged between 97% and 98.5%. The average imprecision of the assay was a >5% coefficient of variation. Assay performance at 2 different cutoffs was evaluated to optimize predictive values. The automated LIAISON SARS-CoV-2 S1/S2 IgG assay brings efficient, sensitive, specific, and precise serological testing to the laboratory, with the capacity to test large amounts of samples per day; first results are available within 35 min, with a throughput of 170 tests/hour. The semiquantitative results provided by the test also associate with the presence of neutralizing antibodies and may provide a useful tool for the large-scale screening of convalescent-phase plasma for safe therapeutic use.
2020
Esperti anonimi
Inglese
Internazionale
ELETTRONICO
58
9
CLIA; COVID-19; Diagnostics; Immunoassays; Immunoserology; Neutralization assay; Neutralizing antibodies; SARS-CoV-2; Spike; Antibodies, Neutralizing; Antibodies, Viral; Automation, Laboratory; Betacoronavirus; COVID-19; COVID-19 Testing; Coronavirus Infections; Humans; Immunoglobulin G; Pandemics; Pneumonia, Viral; Reproducibility of Results; SARS-CoV-2; Sensitivity and Specificity; Spike Glycoprotein, Coronavirus; Clinical Laboratory Techniques; Serologic Tests
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7448652/pdf/JCM.01224-20.pdf
no
14
info:eu-repo/semantics/article
262
Bonelli, F.; Sarasini, A.; Zierold, C.; Calleri, M.; Bonetti, A.; Vismara, C.; Blocki, F. A.; Pallavicini, L.; Chinali, A.; Campisi, D.; Percivalle, E...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1423514
Citazioni
  • ???jsp.display-item.citation.pmc??? 111
  • Scopus 127
  • ???jsp.display-item.citation.isi??? 125
social impact