The purpose of this study was to evaluate boron distribution for a safe and effective BNCT (Boron Neutron Capture Therapy) of liver metastases. Samples both from healthy and tumour liver parenchyma were analysed, after i.v. boron administration, by: a particles counting under neutron irradiation; morphological analysis by standard haematoxylin-eosin staining; neutron autoradiography. Our method was unaffected by the cytological heterogeneity inside tumour nodules; it demonstrated selective boron distribution in tumour tissue and predicted estimated mean therapeutic doses in tumour and safety doses in healthy tissue. The time interval for efficient BNCT was 2 to 4 hours after i.v. boron administration.
How to study boron biodistribution in liver metastases from colorectal cancer
TROTTA, FRANCESCO;MAROTTA, PATRIZIA;ZONTA, ARIS;NANO, ROSANNA;FACOETTI, ANGELICA;CHIARI, PATRIZIA;BARNI, SERGIO;PINELLI, TAZIO;ALTIERI, SAVERIO;FOSSATI, FRANCESCA;
2004-01-01
Abstract
The purpose of this study was to evaluate boron distribution for a safe and effective BNCT (Boron Neutron Capture Therapy) of liver metastases. Samples both from healthy and tumour liver parenchyma were analysed, after i.v. boron administration, by: a particles counting under neutron irradiation; morphological analysis by standard haematoxylin-eosin staining; neutron autoradiography. Our method was unaffected by the cytological heterogeneity inside tumour nodules; it demonstrated selective boron distribution in tumour tissue and predicted estimated mean therapeutic doses in tumour and safety doses in healthy tissue. The time interval for efficient BNCT was 2 to 4 hours after i.v. boron administration.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.