Copper(II) azacyclam complexes (azacyclam = 1,3,5,8,12-pentaazacyclotetradecane) contain- ing naphthyl or dansyl subunits can be prepared by template synthesis involving proper sulfonamide derivatives as locking fragments. The macrocyclic complexes are very poorly emissive due to the fluorescence-quenching behavior displayed by Cu2+ ions. However, the fluorescence can be recovered as a result of the decomposition of the complexes, which induces the release of free light-emitting subunits to the solution. This reaction takes place very slowly in neutral water but its rate is increased by the presence of sulfite. Therefore, [Cu(azacyclam)]2+ derivatives have been investigated as simple chemical probes for the fluorogenic detection of sulfite both on laboratory and real samples. Prelim- inary tests performed on samples of white wine provided sulfite concentration values that are in agreement with those obtained by a standard analytical method.

Fluorogenic Detection of Sulfite in Water by Using Copper(II) Azacyclam Complexes

Ciarrocchi, Carlo;Sacchi, Donatella;Boiocchi, Massimo;Weththimuni, Maduka Lankani;Orbelli Biroli, Alessio;Licchelli, Maurizio
2022-01-01

Abstract

Copper(II) azacyclam complexes (azacyclam = 1,3,5,8,12-pentaazacyclotetradecane) contain- ing naphthyl or dansyl subunits can be prepared by template synthesis involving proper sulfonamide derivatives as locking fragments. The macrocyclic complexes are very poorly emissive due to the fluorescence-quenching behavior displayed by Cu2+ ions. However, the fluorescence can be recovered as a result of the decomposition of the complexes, which induces the release of free light-emitting subunits to the solution. This reaction takes place very slowly in neutral water but its rate is increased by the presence of sulfite. Therefore, [Cu(azacyclam)]2+ derivatives have been investigated as simple chemical probes for the fluorogenic detection of sulfite both on laboratory and real samples. Prelim- inary tests performed on samples of white wine provided sulfite concentration values that are in agreement with those obtained by a standard analytical method.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1452080
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact