The quasi-static in-plane cyclic response of two single-leaf calcium silicate unreinforced masonry piers was investigated to show the effectiveness of an innovative timber retrofit solution. The aim of the intervention is to increase the pier in-plane and out-of-plane strength and displacement capacity, thus reducing the seismic vulnerability of this typology of unreinforced masonry construction with a light, cost-effective, sustainable and reversible approach. The retrofit technique consists of a timber frame mechanically connected by means of steel fasteners to the masonry pier and building floors. Oriented strand timber boards are then nailed to the frame. In-plane quasi-static shear-compression cyclic tests were performed on two single-leaf calcium silicate brick piers with identical geometry and masonry mechanical properties: one was tested unstrengthened while the other was tested in the retrofitted configuration. The experimental results showed evident improvements in the lateral force-displacement response of the retrofitted specimen. More specifically, compared with the bare masonry pier, the retrofitted pier exhibited slightly higher stiffness, larger strength and significantly greater displacement capacity.
Cyclic response of masonry piers retrofitted with timber frames and boards
Guerrini G.;Damiani N.;Miglietta M.;Graziotti F.
2021-01-01
Abstract
The quasi-static in-plane cyclic response of two single-leaf calcium silicate unreinforced masonry piers was investigated to show the effectiveness of an innovative timber retrofit solution. The aim of the intervention is to increase the pier in-plane and out-of-plane strength and displacement capacity, thus reducing the seismic vulnerability of this typology of unreinforced masonry construction with a light, cost-effective, sustainable and reversible approach. The retrofit technique consists of a timber frame mechanically connected by means of steel fasteners to the masonry pier and building floors. Oriented strand timber boards are then nailed to the frame. In-plane quasi-static shear-compression cyclic tests were performed on two single-leaf calcium silicate brick piers with identical geometry and masonry mechanical properties: one was tested unstrengthened while the other was tested in the retrofitted configuration. The experimental results showed evident improvements in the lateral force-displacement response of the retrofitted specimen. More specifically, compared with the bare masonry pier, the retrofitted pier exhibited slightly higher stiffness, larger strength and significantly greater displacement capacity.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.