Dual-three-phase permanent magnet synchronous machines (DTP-PMSMs) are famous for their fault-tolerant capability. However, the complex modeling, high copper loss, and torque ripple under postfault operation limit their further application. In this article, a fault-tolerant control (FTC) strategy is developed for DTP-PMSMs under the open-phase fault (OPF) with straightforward modeling and smooth output torque. The virtual healthy DTP-PMSM model, where the coordinate transformation, the modulation strategy, and the controller structure remain unchanged under OPF, is adopted in the proposed FTC scheme. And the current references are derived in sinusoidal waves with minimum copper loss. The inaccurate transmission of control signals under OPF is also focused on. Comprehensive theoretical analysis shows the relationship between the controller output voltage and the actual stator voltage should be considered in the proposed FTC strategy; otherwise, distortion in torque and current will be introduced. The voltage compensation is utilized to compensate for the voltage difference and ensure the smooth torque output. Besides, a quasi proportional resonance controller is designed to further suppress the residual torque ripple. The proposed strategy will not induce complex implementation and heavy computation burden. The simulation and experimental results prove the analysis and the effectiveness of the proposed strategy. © 1986-2012 IEEE.

Analysis and Fault-Tolerant Control for Dual-Three-Phase PMSM Based on Virtual Healthy Model

Tang M.;Zanchetta P.
2022-01-01

Abstract

Dual-three-phase permanent magnet synchronous machines (DTP-PMSMs) are famous for their fault-tolerant capability. However, the complex modeling, high copper loss, and torque ripple under postfault operation limit their further application. In this article, a fault-tolerant control (FTC) strategy is developed for DTP-PMSMs under the open-phase fault (OPF) with straightforward modeling and smooth output torque. The virtual healthy DTP-PMSM model, where the coordinate transformation, the modulation strategy, and the controller structure remain unchanged under OPF, is adopted in the proposed FTC scheme. And the current references are derived in sinusoidal waves with minimum copper loss. The inaccurate transmission of control signals under OPF is also focused on. Comprehensive theoretical analysis shows the relationship between the controller output voltage and the actual stator voltage should be considered in the proposed FTC strategy; otherwise, distortion in torque and current will be introduced. The voltage compensation is utilized to compensate for the voltage difference and ensure the smooth torque output. Besides, a quasi proportional resonance controller is designed to further suppress the residual torque ripple. The proposed strategy will not induce complex implementation and heavy computation burden. The simulation and experimental results prove the analysis and the effectiveness of the proposed strategy. © 1986-2012 IEEE.
2022
Esperti anonimi
Inglese
Internazionale
ELETTRONICO
37
12
15411
15424
14
Controllers; Fault tolerance; Harmonic analysis; Permanent magnets; Stators; Synchronous motors; Torque; Winding, Copper loss; Dual three-phase; Dual three-phase pmsm; Faults tolerant controls; Modeling; Ripple suppression; Stator winding; Torque ripple suppression; Torque ripples; Voltage constraints, Copper; Copper loss; dual-three-phase permanent magnet synchronous machine (DTP-PMSM); fault-tolerant control (FTC); modeling; torque ripple suppression; voltage constraint
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85136894474&doi=10.1109/TPEL.2022.3199100&partnerID=40&md5=57e986ed517528e548ec649d0fabcb15
6
info:eu-repo/semantics/article
262
Zheng, B.; Zou, J.; Li, B.; Tang, M.; Xu, Y.; Zanchetta, P.
1 Contributo su Rivista::1.1 Articolo in rivista
open
File in questo prodotto:
File Dimensione Formato  
Analysis_and_Fault-Tolerant_Control_for_Dual-Three-Phase_PMSM_Based_on_Virtual_Healthy_Model.pdf

accesso aperto

Dimensione 3.36 MB
Formato Adobe PDF
3.36 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1466892
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 35
social impact