BackgroundA proof-of-concept study to evaluate the feasibility and safety of minimally invasive ultrasound (US)-guided synovial biopsy of the radiocarpal (RC) joint using the anatomical snuffbox as an access route.MethodsTwenty consecutive patients with active chronic arthritis of the wrist underwent minimally invasive US-guided synovial biopsy of the RC joint using the anatomical snuffbox as the access route. Samples were retrieved from 3 predetermined biopsy target sites of the RC synovia (proximal, vault, and distal site), aiming for a minimum of 12 samples. The procedure's feasibility was evaluated based on the number and histological quality of retrieved tissue fragments tested on pre-defined histometric parameters. The safety and tolerability of the procedure were assessed through 1-week and 1-month follow-up clinical evaluations.ResultsA median number of 17 fragments (& GE; 1 mm diameter size at macroscopic evaluation) per procedure was processed for histopathology (range 9-24) and dedicated to the study. At the histopathologic evaluation, a gradable tissue (visible lining layer and & GE; 4 fragments with IST) was recognized in 19/20 biopsies (95%), and all pre-defined histometric parameters were judged applicable and successfully measured in 19/19 gradable biopsies. All three biopsy target sites showed sampling accessibility. The entire procedure was generally well tolerated. At the 1-month follow-up, no patients showed infectious complications.ConclusionsThe access route through the anatomical snuff box in US-guided synovial biopsies of the RC joint allows for a safe and targeted collection of adequate tissue samples. This modification of the traditional access route may allow easier, repeatable, and safer sampling of anatomically distinct areas of the wrist in the course of arthritis.

The access route through the anatomical snuffbox in ultrasound-guided synovial biopsy of the wrist allows for a safe and effective collection of tissue samples in inflammatory arthritis

De Stefano, Ludovico;Bugatti, Serena;Piccin, Veronica;D'Ambrosio, Gioacchino;Luvaro, Terenzj;Xoxi, Blerina;Montecucco, Carlomaurizio;Manzo, Antonio
2023-01-01

Abstract

BackgroundA proof-of-concept study to evaluate the feasibility and safety of minimally invasive ultrasound (US)-guided synovial biopsy of the radiocarpal (RC) joint using the anatomical snuffbox as an access route.MethodsTwenty consecutive patients with active chronic arthritis of the wrist underwent minimally invasive US-guided synovial biopsy of the RC joint using the anatomical snuffbox as the access route. Samples were retrieved from 3 predetermined biopsy target sites of the RC synovia (proximal, vault, and distal site), aiming for a minimum of 12 samples. The procedure's feasibility was evaluated based on the number and histological quality of retrieved tissue fragments tested on pre-defined histometric parameters. The safety and tolerability of the procedure were assessed through 1-week and 1-month follow-up clinical evaluations.ResultsA median number of 17 fragments (& GE; 1 mm diameter size at macroscopic evaluation) per procedure was processed for histopathology (range 9-24) and dedicated to the study. At the histopathologic evaluation, a gradable tissue (visible lining layer and & GE; 4 fragments with IST) was recognized in 19/20 biopsies (95%), and all pre-defined histometric parameters were judged applicable and successfully measured in 19/19 gradable biopsies. All three biopsy target sites showed sampling accessibility. The entire procedure was generally well tolerated. At the 1-month follow-up, no patients showed infectious complications.ConclusionsThe access route through the anatomical snuff box in US-guided synovial biopsies of the RC joint allows for a safe and targeted collection of adequate tissue samples. This modification of the traditional access route may allow easier, repeatable, and safer sampling of anatomically distinct areas of the wrist in the course of arthritis.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1481520
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact