The energy loss of α particles crossing biological tissue at energies between 0.8 and 2.2 MeV has been measured. This energy range is very important for Boron Neutron Capture Therapy, based on the 10B(n,α)7Li reaction, which emits α particles with energies of 1.78 and 1.47 MeV. One of the methods used for the measurement of the boron concentration in tissue is based on the deconvolution of the α spectra obtained from neutron irradiation of thin (70 µm) tissue samples. For this technique, a knowledge of the behaviour of the energy loss of the particles in the irradiated tissue is of critical importance. In particular, the curve of the residual energy as a function of the distance travelled in the tissue must be known. In this paper, the results of an experiment carried out with an 241Am source and a series of cryostatic sections of rat-lung tissue are presented. The experimental measurements are compared with the results of Monte Carlo calculations performed with the MCNPX code.

Measurement of α particle energy loss in biological tissue below 2 MeV

STELLA, SABRINA;BORTOLUSSI, SILVA;BRUSCHI, PIERO;ALTIERI, SAVERIO
2009-01-01

Abstract

The energy loss of α particles crossing biological tissue at energies between 0.8 and 2.2 MeV has been measured. This energy range is very important for Boron Neutron Capture Therapy, based on the 10B(n,α)7Li reaction, which emits α particles with energies of 1.78 and 1.47 MeV. One of the methods used for the measurement of the boron concentration in tissue is based on the deconvolution of the α spectra obtained from neutron irradiation of thin (70 µm) tissue samples. For this technique, a knowledge of the behaviour of the energy loss of the particles in the irradiated tissue is of critical importance. In particular, the curve of the residual energy as a function of the distance travelled in the tissue must be known. In this paper, the results of an experiment carried out with an 241Am source and a series of cryostatic sections of rat-lung tissue are presented. The experimental measurements are compared with the results of Monte Carlo calculations performed with the MCNPX code.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/148389
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact