Beam hodoscopes based on 32 × 32 square polystyrene scintillating fibres along X/Y, having section 3 × 3 mm2 or 1 × 1 mm2, have been designed and characterised for monitoring low-energy charged particle beams. Each fibre is read by a SiPM and the signal is digitised and analysed off-line. Hodoscopes were exposed to the 60 MeV/c negative muon beam at Port 1 of the RIKEN-RAL muon facility (UK), where they proved to be good to determine the beam profile and its intensity, via a calibration with cosmic muons. Furthermore, the exposition to the calibrated single-proton beam at CNAO (Italy), in the momentum range between 340 MeV/c and 690 MeV/c, provided further calibration in dE/dx and showed the feasibility of the detector as an instrument for proton beam characterisation too. These hodoscopes will be used as negative muon beam monitors for the FAMU experiment at the Rutherford Appleton Laboratory, but the possibility of using them as a beam monitor in hadron therapy has also been investigated.

Characterisation of muon and proton beam monitors based on scintillating fibres with a SiPM read-out

Rossini R.
;
Menegolli A.;
2023-01-01

Abstract

Beam hodoscopes based on 32 × 32 square polystyrene scintillating fibres along X/Y, having section 3 × 3 mm2 or 1 × 1 mm2, have been designed and characterised for monitoring low-energy charged particle beams. Each fibre is read by a SiPM and the signal is digitised and analysed off-line. Hodoscopes were exposed to the 60 MeV/c negative muon beam at Port 1 of the RIKEN-RAL muon facility (UK), where they proved to be good to determine the beam profile and its intensity, via a calibration with cosmic muons. Furthermore, the exposition to the calibrated single-proton beam at CNAO (Italy), in the momentum range between 340 MeV/c and 690 MeV/c, provided further calibration in dE/dx and showed the feasibility of the detector as an instrument for proton beam characterisation too. These hodoscopes will be used as negative muon beam monitors for the FAMU experiment at the Rutherford Appleton Laboratory, but the possibility of using them as a beam monitor in hadron therapy has also been investigated.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1486927
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact