Abstract: Axillary artery has been proposed as a safe and effective alternative for arterial cannulation in surgical procedures involving ascending aorta and/or aortic arch, and is nowadays the site of choice in many centres. Advantages of axillary artery cannulation include antegrade flow and the possibility of selective mono-hemispherical brain perfusion during circulatory arrest. Experiences with the axillary vein cannulation, however, are scarce. Here we report our preliminary experience with axillo-axillary cardiopulmonary bypass, through both axillary artery and vein cannulation (using echo-guided Seldinger technique) at deltoido-pectoralis groove. We have used such an approach in 5 cases of redo surgery on ascending aorta and we have not had any inconvenience during cardiopulmonary bypass. Full flow was maintained in all patients (in 2 with vacuum assisted drainage) including 2 cases with deep hypothermic circulatory arrest. In conclusion such an approach seems to be feasible and effective and can be safety performed providing that accurate TE echo monitoring is provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Deltoido pectoralis approach to axillary vessels for full flow cardiopulmonary bypass.

D'ARMINI, ANDREA MARIA;VIGANO', MARIO
2009-01-01

Abstract

Abstract: Axillary artery has been proposed as a safe and effective alternative for arterial cannulation in surgical procedures involving ascending aorta and/or aortic arch, and is nowadays the site of choice in many centres. Advantages of axillary artery cannulation include antegrade flow and the possibility of selective mono-hemispherical brain perfusion during circulatory arrest. Experiences with the axillary vein cannulation, however, are scarce. Here we report our preliminary experience with axillo-axillary cardiopulmonary bypass, through both axillary artery and vein cannulation (using echo-guided Seldinger technique) at deltoido-pectoralis groove. We have used such an approach in 5 cases of redo surgery on ascending aorta and we have not had any inconvenience during cardiopulmonary bypass. Full flow was maintained in all patients (in 2 with vacuum assisted drainage) including 2 cases with deep hypothermic circulatory arrest. In conclusion such an approach seems to be feasible and effective and can be safety performed providing that accurate TE echo monitoring is provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/149278
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact