This paper presents a landmark full-scale experimental program aimed at advancing the understanding of long-term performance of seismic base isolation for buildings in real service conditions. A three-story residential structure in Arischia (L'Aquila, Italy), base-isolated with Friction Pendulum (FP) bearings in service for over 15 years, was subjected to in-situ dynamic testing. Using custom-designed self-reacting frames and the EUCENTRE's mobile laboratory, displacement-controlled sinusoidal loading histories were applied, covering a range of amplitudes and peak velocities. This paper details the test specimen, experimental setup, loading protocols, and instrumentation. It presents preliminary findings on key isolation system properties, including post-elastic stiffness, static and dynamic friction coefficients, and equivalent damping ratio. These results provide rare field-based insight into the effects of aging on FP isolators and offer critical validation data for models used in performance-based assessment of base-isolated structures. In addition, the study demonstrates the feasibility and value of in-situ testing, which can serve as a model for future full-scale investigations of base-isolated buildings.

Dynamic field testing of a 15-year-old friction pendulum base-isolated residential building

Calvi P. M.
;
Gabbianelli G.;Chalarca Echeverri B.;
2026-01-01

Abstract

This paper presents a landmark full-scale experimental program aimed at advancing the understanding of long-term performance of seismic base isolation for buildings in real service conditions. A three-story residential structure in Arischia (L'Aquila, Italy), base-isolated with Friction Pendulum (FP) bearings in service for over 15 years, was subjected to in-situ dynamic testing. Using custom-designed self-reacting frames and the EUCENTRE's mobile laboratory, displacement-controlled sinusoidal loading histories were applied, covering a range of amplitudes and peak velocities. This paper details the test specimen, experimental setup, loading protocols, and instrumentation. It presents preliminary findings on key isolation system properties, including post-elastic stiffness, static and dynamic friction coefficients, and equivalent damping ratio. These results provide rare field-based insight into the effects of aging on FP isolators and offer critical validation data for models used in performance-based assessment of base-isolated structures. In addition, the study demonstrates the feasibility and value of in-situ testing, which can serve as a model for future full-scale investigations of base-isolated buildings.
2026
Civil Engineering covers engineering-based resources in the subfields of structural engineering, geotechnics, earthquake engineering, ocean engineering, water resources and supply, naval engineering, marine engineering, transportation engineering, and municipal engineering. Topics covered include the planning, design, construction, and maintenance of fixed structures and ground facilities for industry, occupancy, transportation, use and control of water, and harbor facilities.
Esperti anonimi
Inglese
Internazionale
200
10
info:eu-repo/semantics/article
262
Calvi, P. M.; Rapone, A.; Becker, T. C.; Sucuoglu, H.; Gabbianelli, G.; Chalarca Echeverri, B.; Lanese, I.; O'Reilly, G. J.; Rizzo-Parisi, E.; Dacarro...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1531795
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
social impact