The combination of a Cherenkov radiator with a semi transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15 ps. While tileable prototypes with 10×10 channels feature 1 × 1 cm 2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5 mm spatial resolution with 3.5 mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2 mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20 ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

Brunoldi, M.
Membro del Collaboration Group
;
Vai, I.
Membro del Collaboration Group
;
Vitulo, P.
Membro del Collaboration Group
;
2026-01-01

Abstract

The combination of a Cherenkov radiator with a semi transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15 ps. While tileable prototypes with 10×10 channels feature 1 × 1 cm 2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5 mm spatial resolution with 3.5 mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2 mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20 ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.
2026
Esperti anonimi
Inglese
Internazionale
ELETTRONICO
21
05
Gaseous detectors; Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Timing detectors
https://iopscience.iop.org/article/10.1088/1748-0221/21/05/P05003
50
info:eu-repo/semantics/article
262
Brunbauer, F. M.; Aleksan, R.; Angelis, Y.; Aune, S.; Bortfeldt, J.; Brunoldi, M.; Datta, J.; Desforge, D.; Fanourakis, G.; Fiorina, D.; Floethner, K....espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1551804
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact