X-ray tubes are sources of X-rays used in various fields, ranging from radiographic imaging in medical physics to the characterization of detectors in particle physics. This article presents a method for the complete characterization of the Mini-X2 X-Ray tube from AMETEK, an X-ray source later used to characterize gas detectors in laboratory. Using data provided by the manual, we derive key operational parameters onof the tube, such as the photon emission rate and the relationship between emissive power and supplied current. Based on this characterization, we determine the air dose rate as well as the absorbed dose rate within a given volume at various distances from the source. We derive this dose experimentally, theoretically and through simulations and find good agreement between these. To enable safe operation in a laboratory environment and to support experimental comparisons, a shielding system was developed. It will be therefore illustrated how the shielding containing the Mini-X2 has been designed, exploiting the simulation power of the Geant4 software. In the last section, as a first application on the characterized X-Ray tube, we present the result on a Triple-GEM sensitivity measurement to photons.

Characterization of an X-Ray tube and photon sensitivity studies with Triple-GEM detectors using combined measurements and Geant4 simulations

Brunoldi, M.;Calzaferri, S.;Pelliccioni, M.;Salvini, P.;Tamigio, A.;Vai, I.;Vitulo, P.
2026-01-01

Abstract

X-ray tubes are sources of X-rays used in various fields, ranging from radiographic imaging in medical physics to the characterization of detectors in particle physics. This article presents a method for the complete characterization of the Mini-X2 X-Ray tube from AMETEK, an X-ray source later used to characterize gas detectors in laboratory. Using data provided by the manual, we derive key operational parameters onof the tube, such as the photon emission rate and the relationship between emissive power and supplied current. Based on this characterization, we determine the air dose rate as well as the absorbed dose rate within a given volume at various distances from the source. We derive this dose experimentally, theoretically and through simulations and find good agreement between these. To enable safe operation in a laboratory environment and to support experimental comparisons, a shielding system was developed. It will be therefore illustrated how the shielding containing the Mini-X2 has been designed, exploiting the simulation power of the Geant4 software. In the last section, as a first application on the characterized X-Ray tube, we present the result on a Triple-GEM sensitivity measurement to photons.
2026
Inglese
21
03
Detector modelling and simulations I (interaction of radiation with matter, interaction of photons with matter, interaction of hadrons with matter, etc); X-ray generators and sources
no
8
info:eu-repo/semantics/article
262
Braghieri, A.; Brunoldi, M.; Calzaferri, S.; Pelliccioni, M.; Salvini, P.; Tamigio, A.; Vai, I.; Vitulo, P.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1552656