The aim of the study was to evaluate the effect of pulse vs. continuous irradiation on the shear bond strength of a conventional orthodontic composite resin cured with a microxenon light (Aurys, Degre` K, Schiltigheim, France). Ninety freshly extracted bovine permanent mandibular incisors were randomly assigned to one of six groups; each group consisting of 15 specimens. Three groups were exposed to continuous irradiation of micro-xenon light for 10, 5, and 2 s, respectively, and used as controls. The remaining three groups were exposed to pulse irradiation of the same light source for 10, 5, and 2 s, respectively. After 24 h, all samples were tested in a shear mode on an Instron Machine (Instron Corp., Canton, MA, USA). Analysis was made by ANOVA with Scheffe´ ’s test for comparisons. The chi-square test was used to determine significant differences in the Adhesive Remnant Index scores. The mean shear bond strength of the brackets continuously cured for 10 s was not statistically different from that of the brackets pulse-activated for the same curing time. Also, no statistically significant differences were found between both groups cured for 5 s. The group pulse-activated for 5 s, however, had a significantly lower mean shear bond strength than the control group cured for 10 s. Finally, the group pulse-activated for 2 s showed significantly lower bond strength values than all the other groups tested. Compared with continuous light curing, the micro-xenon pulse activation provides similar shear bond strength values, except when used for only 2 s; but despite lower performance characteristics, the shear bond strength may be clinically acceptable.

Effect of pulse vs continuous micro-xenon irradiation on the shear bond strength of a light-cured orthodontic composite resin

SFONDRINI, MARIA FRANCESCA;SFONDRINI, GIUSEPPE;
2003-01-01

Abstract

The aim of the study was to evaluate the effect of pulse vs. continuous irradiation on the shear bond strength of a conventional orthodontic composite resin cured with a microxenon light (Aurys, Degre` K, Schiltigheim, France). Ninety freshly extracted bovine permanent mandibular incisors were randomly assigned to one of six groups; each group consisting of 15 specimens. Three groups were exposed to continuous irradiation of micro-xenon light for 10, 5, and 2 s, respectively, and used as controls. The remaining three groups were exposed to pulse irradiation of the same light source for 10, 5, and 2 s, respectively. After 24 h, all samples were tested in a shear mode on an Instron Machine (Instron Corp., Canton, MA, USA). Analysis was made by ANOVA with Scheffe´ ’s test for comparisons. The chi-square test was used to determine significant differences in the Adhesive Remnant Index scores. The mean shear bond strength of the brackets continuously cured for 10 s was not statistically different from that of the brackets pulse-activated for the same curing time. Also, no statistically significant differences were found between both groups cured for 5 s. The group pulse-activated for 5 s, however, had a significantly lower mean shear bond strength than the control group cured for 10 s. Finally, the group pulse-activated for 2 s showed significantly lower bond strength values than all the other groups tested. Compared with continuous light curing, the micro-xenon pulse activation provides similar shear bond strength values, except when used for only 2 s; but despite lower performance characteristics, the shear bond strength may be clinically acceptable.
2003
The Dentistry/Oral Surgery & Medicine category covers resources concerned with all aspects of dental science and practice including dental implants and dental materials. Specialties such as orthodontics, periodontology, endodontics, prosthodontics, and pediatric dentistry are also included. Oral Surgery & Medicine resources are concerned with basic, applied, and clinical aspects of oral infections and diseases, including their epidemiology, diagnosis, treatment, and rehabilitation. Specialties such as oral pathology/biology, oral epidemiology, oral rehabilitation, and oral implants are also included. Facial pain and craniomandibular resources are also covered in this category.
Esperti anonimi
Inglese
Internazionale
STAMPA
4
1
31
36
6
Tematica Ex SIR: forze di distacco in ortodonzia (Classif. Ex SIR:Articoli su riviste scientifiche Index Medicus, Science Citation Index )
bond strength; orthodontic bonding; orthodontic brackets; pulse irradiation; xenon arc light curing
4
info:eu-repo/semantics/article
262
Sfondrini, MARIA FRANCESCA; Cacciafesta, Vittorio; Sfondrini, Giuseppe; Klersy, Catherine
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/17295
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact