Abstract: Objective: We assessed the surgical results and the benefits to the patient of a minimally invasive surgical approach for atrial septal defects. Methods: Between May 1998 and May 2008, 166 patients (median age, 44 years) had surgery for atrial septal defects in our institution. Of these patients, 118 (71%) had a patent foramen ovale (associated with atrial septal aneurysm in 48 cases), 33 (20%) had a wide ostium secundum defect, 6 (3.6%) had an ostium primum defect, 6 (3.6%) had a sinus venosus defect with abnormal pulmonary vein connection, and 1 (0.6%) had a coronary sinus defect. In 2 cases (1.2%) patients were referred to our department for surgical correction after failure of interventional occluder placement. All patients were operated on via a right minithoracotomy (mean incision, 5.5 +/- 1 cm) in the fourth intercostal space and under cardiopulmonary bypass. Results: The HeartPort access system was used in 106 patients (64%), with an endoaortic clamp (central kit in 50 cases and peripheral kit in 56). In the remaining patients (36%), we preferred the Portaclamp system (37 cases) or the Chitwood clamp (23 cases). Average crossclamp time was 38.4 +/- 22.2 minutes with a mean cardiopulmonary bypass time of 64.9 +/- 34.5 minutes. There was no conversion in classic sternotomy. There were no early or late hospital deaths. Surgical revision was performed in 6 patients for bleeding from the thoracic wall. The mean hospital stay was 5.8 days. At 51 months mean follow-up, 4 patients died of non-cardiac-related causes. Conclusions: Port-access minimally invasive surgery for atrial septal defects is a safe, less-invasive, reproducible, and cosmetic operation, providing an excellent outcome and an effective correction, and could be now considered the standard approach for this type of patient.(J Thorac Cardiovasc Surg 2010; 139: 139-45)

Port-access minimally invasive surgery for atrial septal defects: A 10-years single-center experience in 166 patients

VISTARINI, NICOLA LUIGI CARLO;ALLONI, ALESSIA;CATTADORI, BARBARA;PELLEGRINI, CARLO;D'ARMINI, ANDREA MARIA;VIGANO', MARIO
2010-01-01

Abstract

Abstract: Objective: We assessed the surgical results and the benefits to the patient of a minimally invasive surgical approach for atrial septal defects. Methods: Between May 1998 and May 2008, 166 patients (median age, 44 years) had surgery for atrial septal defects in our institution. Of these patients, 118 (71%) had a patent foramen ovale (associated with atrial septal aneurysm in 48 cases), 33 (20%) had a wide ostium secundum defect, 6 (3.6%) had an ostium primum defect, 6 (3.6%) had a sinus venosus defect with abnormal pulmonary vein connection, and 1 (0.6%) had a coronary sinus defect. In 2 cases (1.2%) patients were referred to our department for surgical correction after failure of interventional occluder placement. All patients were operated on via a right minithoracotomy (mean incision, 5.5 +/- 1 cm) in the fourth intercostal space and under cardiopulmonary bypass. Results: The HeartPort access system was used in 106 patients (64%), with an endoaortic clamp (central kit in 50 cases and peripheral kit in 56). In the remaining patients (36%), we preferred the Portaclamp system (37 cases) or the Chitwood clamp (23 cases). Average crossclamp time was 38.4 +/- 22.2 minutes with a mean cardiopulmonary bypass time of 64.9 +/- 34.5 minutes. There was no conversion in classic sternotomy. There were no early or late hospital deaths. Surgical revision was performed in 6 patients for bleeding from the thoracic wall. The mean hospital stay was 5.8 days. At 51 months mean follow-up, 4 patients died of non-cardiac-related causes. Conclusions: Port-access minimally invasive surgery for atrial septal defects is a safe, less-invasive, reproducible, and cosmetic operation, providing an excellent outcome and an effective correction, and could be now considered the standard approach for this type of patient.(J Thorac Cardiovasc Surg 2010; 139: 139-45)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/204799
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 40
social impact