AIMS: The European cardiac resynchronization therapy (CRT) survey is a joint initiative taken by the Heart Failure Association and the European Heart Rhythm Association of the European Society of Cardiology. The primary aim of this survey is to describe current European practice associated with CRT implantations. METHODS AND RESULTS: A total of 140 centres from 13 European countries contributed data from consecutive patients successfully implanted with a CRT device with or without an ICD between November 2008 and June 2009. The total number of patients enrolled was 2438. The median age of the patients was 70 years (IQR 62-76) and 31% were > or =75 years. It was found that 78% were in NYHA functional class III or IV and 22% in I or II. The mean ejection fraction was 27% +/- 8 and the mean QRS duration 157 ms +/- 32. The QRS duration was <120 ms in 9%. Atrial fibrillation was reported in 23%. It was found that 26% of patients had a previously implanted permanent pacemaker or ICD; 76% of procedures were performed by an electrophysiologist; 82% had an elective admission for implantation and the median duration of hospitalization was 3 days (IQR 2-7); and 73% received a CRT-D device which was more often implanted in men, younger patients, and with ischaemic aetiology. The mean QRS duration was reduced to 133 ms +/- 27 (P < 0.0001) at discharge. Peri-procedural complication rates were comparable to the rates reported in randomized trials. CONCLUSION: This CRT survey provides important information describing current European practice with regard to patient demographics, selection criteria, procedural routines, and status at discharge. These data should be useful for benchmarking individual patient management and national practice against wider experience.

The European cardiac resynchronization therapy survey

PRIORI, SILVIA GIULIANA;
2009-01-01

Abstract

AIMS: The European cardiac resynchronization therapy (CRT) survey is a joint initiative taken by the Heart Failure Association and the European Heart Rhythm Association of the European Society of Cardiology. The primary aim of this survey is to describe current European practice associated with CRT implantations. METHODS AND RESULTS: A total of 140 centres from 13 European countries contributed data from consecutive patients successfully implanted with a CRT device with or without an ICD between November 2008 and June 2009. The total number of patients enrolled was 2438. The median age of the patients was 70 years (IQR 62-76) and 31% were > or =75 years. It was found that 78% were in NYHA functional class III or IV and 22% in I or II. The mean ejection fraction was 27% +/- 8 and the mean QRS duration 157 ms +/- 32. The QRS duration was <120 ms in 9%. Atrial fibrillation was reported in 23%. It was found that 26% of patients had a previously implanted permanent pacemaker or ICD; 76% of procedures were performed by an electrophysiologist; 82% had an elective admission for implantation and the median duration of hospitalization was 3 days (IQR 2-7); and 73% received a CRT-D device which was more often implanted in men, younger patients, and with ischaemic aetiology. The mean QRS duration was reduced to 133 ms +/- 27 (P < 0.0001) at discharge. Peri-procedural complication rates were comparable to the rates reported in randomized trials. CONCLUSION: This CRT survey provides important information describing current European practice with regard to patient demographics, selection criteria, procedural routines, and status at discharge. These data should be useful for benchmarking individual patient management and national practice against wider experience.
2009
Cardiovascular & Hematology Research covers all levels of investigation into the normal and pathogenic functions of the heart, vasculature, and soluble blood components. Cell biology of vascular tissue and formed elements of blood, biochemical regulation of thrombosis, therapeutic strategies for treatment of cardiac and vascular diseases are also considered. Resources on hematologic oncology are excluded and are placed in the Oncogenesis & Cancer Research category.
Sì, ma tipo non specificato
Inglese
Internazionale
ELETTRONICO
30
20
2450
2460
11
CRT; permanent pacemaker; QRS
10
info:eu-repo/semantics/article
262
Dickstein, K; Bogale, N; Priori, SILVIA GIULIANA; Auricchio, A; Cleland, Jg; Gitt, A; Limbourg, T; Linde, C; van Veldhuisen, Dj; Brugada, J.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/210824
Citazioni
  • ???jsp.display-item.citation.pmc??? 53
  • Scopus 223
  • ???jsp.display-item.citation.isi??? 189
social impact