This study measured and compared the level of frictional resistance generated between stainless steel self-ligating brackets (Damon SL II, SDS Ormco, Glendora, Calif), polycarbonate self-ligating brackets (Oyster, Gestenco International, Göthenburg, Sweden), and conventional stainless steel brackets (Victory Series, 3M Unitek, Monrovia, Calif), and 3 different orthodontic wire alloys: stainless steel (Stainless Steel, SDS Ormco), nickel-titanium (Ni-Ti, SDS Ormco), and beta-titanium (TMA, SDS Ormco). All brackets had a.022-in slot, whereas the orthodontic wire alloys were tested in 3 different sections:.016,.017 x.025, and.019 x 0.025 in. Each of the 27 bracket and archwire combinations was tested 10 times, and each test was performed with a new bracket-wire sample. Both static and kinetic friction were measured on a custom-designed apparatus. All data were statistically analyzed (Kruskal-Wallis and Mann Whitney U tests). Stainless steel self-ligating brackets generated significantly lower static and kinetic frictional forces than both conventional stainless steel and polycarbonate self-ligating brackets, which showed no significant differences between them. Beta-titanium archwires had higher frictional resistances than stainless steel and nickel-titanium archwires. No significant differences were found between stainless steel and nickel-titanium archwires. All brackets showed higher static and kinetic frictional forces as the wire size increased.

Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations

SFONDRINI, MARIA FRANCESCA;SCRIBANTE, ANDREA;AURICCHIO, FERDINANDO
2003-01-01

Abstract

This study measured and compared the level of frictional resistance generated between stainless steel self-ligating brackets (Damon SL II, SDS Ormco, Glendora, Calif), polycarbonate self-ligating brackets (Oyster, Gestenco International, Göthenburg, Sweden), and conventional stainless steel brackets (Victory Series, 3M Unitek, Monrovia, Calif), and 3 different orthodontic wire alloys: stainless steel (Stainless Steel, SDS Ormco), nickel-titanium (Ni-Ti, SDS Ormco), and beta-titanium (TMA, SDS Ormco). All brackets had a.022-in slot, whereas the orthodontic wire alloys were tested in 3 different sections:.016,.017 x.025, and.019 x 0.025 in. Each of the 27 bracket and archwire combinations was tested 10 times, and each test was performed with a new bracket-wire sample. Both static and kinetic friction were measured on a custom-designed apparatus. All data were statistically analyzed (Kruskal-Wallis and Mann Whitney U tests). Stainless steel self-ligating brackets generated significantly lower static and kinetic frictional forces than both conventional stainless steel and polycarbonate self-ligating brackets, which showed no significant differences between them. Beta-titanium archwires had higher frictional resistances than stainless steel and nickel-titanium archwires. No significant differences were found between stainless steel and nickel-titanium archwires. All brackets showed higher static and kinetic frictional forces as the wire size increased.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/223624
Citazioni
  • ???jsp.display-item.citation.pmc??? 44
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 97
social impact