INTRODUCTION: Experience in endovascular/endocardial techniques for implanting implantable cardioverter defibrillators in early childhood is limited. Potentially, this type of approach could limit the surgical risk, while increasing ICD therapy efficacy. The safety and feasibility of adopting a complete endovascular/endocardial approach for implanting ICDs is assessed by considering the cases of two young children. METHODS AND RESULTS: Two boys, aged 3 and 6 years, were implanted with ICD for a history of syncope and documented ventricular tachycardia (VT). A complete endovascular/endocardial approach was adopted consisting of positioning a bipolar pacing and sensing lead in the right ventricular (RV) apex with intravascular redundancy forming a loop in the inferior vena cava (IVC), and a caval coil placed in the IVC. Sensing values (7-8 mV), pacing threshold (0.5-0.6 V/0.5 msec), and defibrillation testing (case 1 = 10 J, case 2 = 20 J) were all acceptable. During follow-up, in both cases ICD intervened correctly. In one case, 16 months after implantation, because of change in the IVC coil-active can vector, the IVC coil was effectively repositioned to a more distal position. CONCLUSION: A complete endovascular/endocardial ICD implantation technique in early childhood is both feasible and safe. This approach avoids thoracotomy and ensures ICD therapy efficacy.

Endocardial implantation of a cardioverter defibrillator in early childhood.

PRIORI, SILVIA GIULIANA
2005-01-01

Abstract

INTRODUCTION: Experience in endovascular/endocardial techniques for implanting implantable cardioverter defibrillators in early childhood is limited. Potentially, this type of approach could limit the surgical risk, while increasing ICD therapy efficacy. The safety and feasibility of adopting a complete endovascular/endocardial approach for implanting ICDs is assessed by considering the cases of two young children. METHODS AND RESULTS: Two boys, aged 3 and 6 years, were implanted with ICD for a history of syncope and documented ventricular tachycardia (VT). A complete endovascular/endocardial approach was adopted consisting of positioning a bipolar pacing and sensing lead in the right ventricular (RV) apex with intravascular redundancy forming a loop in the inferior vena cava (IVC), and a caval coil placed in the IVC. Sensing values (7-8 mV), pacing threshold (0.5-0.6 V/0.5 msec), and defibrillation testing (case 1 = 10 J, case 2 = 20 J) were all acceptable. During follow-up, in both cases ICD intervened correctly. In one case, 16 months after implantation, because of change in the IVC coil-active can vector, the IVC coil was effectively repositioned to a more distal position. CONCLUSION: A complete endovascular/endocardial ICD implantation technique in early childhood is both feasible and safe. This approach avoids thoracotomy and ensures ICD therapy efficacy.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/26677
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact