The purpose of this study was to assess the effect of light-tip distance on the shear bond strength and failure site of brackets cured with three different light curing units: a high-intensity halogen (Astralis 10, 10-second curing), a light-emitting diode (LED, e-Light, six-second curing), and a plasma arc (PAC System, four-second curing). One hundred and thirty-five bovine permanent mandibular incisors were randomly allocated to nine groups of 15 specimens each. Stainless steel brackets were bonded with a composite resin to the teeth, and each curing light was tested at zero, three, and six mm from the bracket. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength. When the three light curing units were compared at a light-tip distance of zero mm, the three lights showed no significantly different shear bond strengths. At light-tip distances of three and six mm, no significant differences were found between the halogen and plasma arc lights, but both lights showed significantly higher shear bond strengths than the LED light. When evaluating the effect of the light-tip distance on each light curing unit, the halogen light showed no significant differences between the three distances. However, the LED light produced significantly lower shear bond strengths at a greater light-tip distance, and the plasma arc lamp showed significantly higher shear bond strengths at a greater light-tip distance. In hard-to-reach areas, the use of PAC system is suggested, whereas the LED evaluated in this study is not recommended.

Effect of light-tip distance on the shear bond strengths of composite resin.

SFONDRINI, MARIA FRANCESCA;SCRIBANTE, ANDREA;
2005-01-01

Abstract

The purpose of this study was to assess the effect of light-tip distance on the shear bond strength and failure site of brackets cured with three different light curing units: a high-intensity halogen (Astralis 10, 10-second curing), a light-emitting diode (LED, e-Light, six-second curing), and a plasma arc (PAC System, four-second curing). One hundred and thirty-five bovine permanent mandibular incisors were randomly allocated to nine groups of 15 specimens each. Stainless steel brackets were bonded with a composite resin to the teeth, and each curing light was tested at zero, three, and six mm from the bracket. After bonding, all samples were stored in distilled water at room temperature for 24 hours and subsequently tested for shear bond strength. When the three light curing units were compared at a light-tip distance of zero mm, the three lights showed no significantly different shear bond strengths. At light-tip distances of three and six mm, no significant differences were found between the halogen and plasma arc lights, but both lights showed significantly higher shear bond strengths than the LED light. When evaluating the effect of the light-tip distance on each light curing unit, the halogen light showed no significant differences between the three distances. However, the LED light produced significantly lower shear bond strengths at a greater light-tip distance, and the plasma arc lamp showed significantly higher shear bond strengths at a greater light-tip distance. In hard-to-reach areas, the use of PAC system is suggested, whereas the LED evaluated in this study is not recommended.
2005
The Dentistry/Oral Surgery & Medicine category covers resources concerned with all aspects of dental science and practice including dental implants and dental materials. Specialties such as orthodontics, periodontology, endodontics, prosthodontics, and pediatric dentistry are also included. Oral Surgery & Medicine resources are concerned with basic, applied, and clinical aspects of oral infections and diseases, including their epidemiology, diagnosis, treatment, and rehabilitation. Specialties such as oral pathology/biology, oral epidemiology, oral rehabilitation, and oral implants are also included. Facial pain and craniomandibular resources are also covered in this category.
Sì, ma tipo non specificato
Inglese
Internazionale
STAMPA
75
3
386
391
6
Tematica Ex SIR: Adesivi per ortodonzia e polimerizzazione (Classif. Ex SIR:Articoli su riviste ISI )
light-tip distance; shear bond strength; failure site; orthodontic brackets; high-intensity halogen light; light-emitting diode; plasma arc
5
info:eu-repo/semantics/article
262
Cacciafesta, Vittorio; Sfondrini, MARIA FRANCESCA; Scribante, Andrea; Boehme, Andreas; Jost Brinkmann Paul, George
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/27124
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? ND
social impact