INTRODUCTION: The purpose of this study was to evaluate the effect of hand light-curing (Optilux 501; SDS Kerr, Danbury, Conn) and secondary oven polymerization (Liculite; Dentsply, Dreieich, Germany) on the mechanical properties of 2 sizes (diameters, 0.6 and 1.2 mm) of fiber-reinforced composites (FRCs) (Ever Stick; Stick Tech, Turku, Finland). METHODS: The FRC samples were divided into 8 groups. Each group consisted of 10 specimens. Each FRC sample was evaluated with a 3-point bending test with a universal testing machine. Groups 1, 3, 5, and 7 were hand light-cured with a halogen curing unit for 40 seconds. Groups 2, 4, 6, and 8 were light-cured with the same curing unit for 40 seconds, followed by polymerization for 15 minutes in a light-curing oven. Groups 1 through 4 were tested at 1-mm deflection, and groups 5 through 8 at 2-mmdeflection. RESULTS: The results of ANOVA indicated significant differences among the various groups (P = .000). The post-hoc test showed that the 2-mm deflection groups had significantly higher flexural strengths than the 1-mm deflection groups (P = .000). Moreover, the 1.2-mm FRCs showed significantly higher flexural strength than the 0.6-mm FRCs (P = .000). No significant differences (P >.05) were found between the hand light-cured and the oven-polymerized groups. CONCLUSIONS: This investigation demonstrated that oven postcuring does not increase the flexural strength values of 0.6- and 1.2-mm FRCs compared with conventional hand light-curing. Thus, hand light-curing of FRCs is recommended directly in the mouth for orthodontic purposes.

Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring

SFONDRINI, MARIA FRANCESCA;SCRIBANTE, ANDREA;
2007-01-01

Abstract

INTRODUCTION: The purpose of this study was to evaluate the effect of hand light-curing (Optilux 501; SDS Kerr, Danbury, Conn) and secondary oven polymerization (Liculite; Dentsply, Dreieich, Germany) on the mechanical properties of 2 sizes (diameters, 0.6 and 1.2 mm) of fiber-reinforced composites (FRCs) (Ever Stick; Stick Tech, Turku, Finland). METHODS: The FRC samples were divided into 8 groups. Each group consisted of 10 specimens. Each FRC sample was evaluated with a 3-point bending test with a universal testing machine. Groups 1, 3, 5, and 7 were hand light-cured with a halogen curing unit for 40 seconds. Groups 2, 4, 6, and 8 were light-cured with the same curing unit for 40 seconds, followed by polymerization for 15 minutes in a light-curing oven. Groups 1 through 4 were tested at 1-mm deflection, and groups 5 through 8 at 2-mmdeflection. RESULTS: The results of ANOVA indicated significant differences among the various groups (P = .000). The post-hoc test showed that the 2-mm deflection groups had significantly higher flexural strengths than the 1-mm deflection groups (P = .000). Moreover, the 1.2-mm FRCs showed significantly higher flexural strength than the 0.6-mm FRCs (P = .000). No significant differences (P >.05) were found between the hand light-cured and the oven-polymerized groups. CONCLUSIONS: This investigation demonstrated that oven postcuring does not increase the flexural strength values of 0.6- and 1.2-mm FRCs compared with conventional hand light-curing. Thus, hand light-curing of FRCs is recommended directly in the mouth for orthodontic purposes.
2007
The Dentistry/Oral Surgery & Medicine category covers resources concerned with all aspects of dental science and practice including dental implants and dental materials. Specialties such as orthodontics, periodontology, endodontics, prosthodontics, and pediatric dentistry are also included. Oral Surgery & Medicine resources are concerned with basic, applied, and clinical aspects of oral infections and diseases, including their epidemiology, diagnosis, treatment, and rehabilitation. Specialties such as oral pathology/biology, oral epidemiology, oral rehabilitation, and oral implants are also included. Facial pain and craniomandibular resources are also covered in this category.
Sì, ma tipo non specificato
Inglese
Internazionale
STAMPA
132
4
524
527
4
Tematica Ex SIR: Adesivi per ortodonzia e polimerizzazione (Classif. Ex SIR:Articoli su riviste ISI )
Flexural strength; fiber-reinforced composites; additional postcuring
6
info:eu-repo/semantics/article
262
Cacciafesta, Vittorio; Sfondrini, MARIA FRANCESCA; Lena, Alessandro; Scribante, Andrea; Vallittu, Pekka; Lassila, Lippo
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/35258
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 52
  • ???jsp.display-item.citation.isi??? ND
social impact