Liver biopsy is crucial in defining natural history and therapeutic choices in chronic hepatitis C and it is usually performed with coarse (>1 mm) needles (CN). As fine needles (FN) do not require anaesthesia, are used over a wider range of coagulation values and allow multiple passes, we compared the diagnostic yield of FN vs. CN biopsies.Paired samples obtained with FN (0.8 mm) and CN (1.2 mm) on 149 consecutive outpatients from a tertiary care institution were evaluated prospectively. Histologic variables were quantitatively scored. Sensitivity, specificity, positive predictive value, negative predictive value and positive likelihood ratio were calculated as measures of diagnostic ability assuming CN as reference.FN biopsy was adequate in 83 cases, CN in 140 cases (P<0.001). Considering the 83 paired adequate specimens, the best sensitivity of FN vs. CN was for portal inflammation (0.95\%) and the worst for cirrhosis (0.33\%). Overall discriminant ability of FN was unsatisfactory and histologic variables were systematically underscored. Tolerability was good for both procedures.The advantages of FN biopsy are lost on its inferior diagnostic performance. Its use in diffuse liver diseases should be restricted to early non-fibrotic lesions.

Coarse vs. fine needle aspiration biopsy for the assessment of diffuse liver disease from hepatitis C virus-related chronic hepatitis.

BRUNETTI, ENRICO;SILINI, ENRICO MARIA;BRUNO, RAFFAELE;FILICE, CARLO
2004-01-01

Abstract

Liver biopsy is crucial in defining natural history and therapeutic choices in chronic hepatitis C and it is usually performed with coarse (>1 mm) needles (CN). As fine needles (FN) do not require anaesthesia, are used over a wider range of coagulation values and allow multiple passes, we compared the diagnostic yield of FN vs. CN biopsies.Paired samples obtained with FN (0.8 mm) and CN (1.2 mm) on 149 consecutive outpatients from a tertiary care institution were evaluated prospectively. Histologic variables were quantitatively scored. Sensitivity, specificity, positive predictive value, negative predictive value and positive likelihood ratio were calculated as measures of diagnostic ability assuming CN as reference.FN biopsy was adequate in 83 cases, CN in 140 cases (P<0.001). Considering the 83 paired adequate specimens, the best sensitivity of FN vs. CN was for portal inflammation (0.95\%) and the worst for cirrhosis (0.33\%). Overall discriminant ability of FN was unsatisfactory and histologic variables were systematically underscored. Tolerability was good for both procedures.The advantages of FN biopsy are lost on its inferior diagnostic performance. Its use in diffuse liver diseases should be restricted to early non-fibrotic lesions.
2004
The Gastroenterology and Hepatology category covers general and investigative gastroenterology and hepatology resources including those concerned with the structure, function, and diseases of the digestive system, stomach, intestines, colon, rectum, and the liver.
Sì, ma tipo non specificato
Inglese
Internazionale
STAMPA
40
3
501
506
6
Adult, Aged, Biopsy; Needle; standards, Biopsy; standards, Cohort Studies, Diagnosis; Differential, Female, Hepatitis C; Chronic; pathology, Humans, Likelihood Functions, Liver Diseases; pathology, Liver; pathology, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Sensitivity and Specificity
http://dx.doi.org/10.1016/j.jhep.2003.11.008
7
info:eu-repo/semantics/article
262
Brunetti, Enrico; Silini, ENRICO MARIA; A., Pistorio; A., Cavallero; A., Marangio; Bruno, Raffaele; Filice, Carlo
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/393319
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 36
social impact