The major limitation implicit in the endovascular procedures for aortic prosthetic substitution is that they cannot be used in these tracts of the aorta where important collateral branches originate (aortic arch, thoraco-abdominal tract, upper abdominal), that would be occluded by the prosthesis. In order to overcome this limitation we hypothesized the endovascular positioning of a prosthesis in the form of a wide mesh network that would be gradually and spontaneously covered by new intima and included in the aortic wall. The fabric framework linked to the aortic wall would then condition its significant, regular and uniform mechanical strengthening that fractionates and partially absorbs the centrifuge pulsatile stress of the bloodstream. The purpose of this paper is to report the results of the insertion of a braided Prolene net prosthesis in the first 7 cm of the descending aorta of ten swine. The animals were killed after 6 weeks, the substituted segment removed and aortic wall compliance measured under standardized conditions. The prosthesis was found entirely covered by new intima, well embodied in the aortic wall. The intercostal collateral included in the substituted segment was patent, as proved by bubble formation during underwater insufflation. Compliance of the prosthesis segment was significantly lower than that of the adjacent descending aorta. Histology showed a regular net prosthesis inclusion deep in the neo-intima layer. Present results indicate the technical feasibility of the procedure, achieving significant aortic wall. strengthening without affecting the collateral (intercostal) circulation.

Aortic wall structural strengthening by intraluminal net prosthesis to arrest aneurysm progression and to prevent dissection and rupture

CARLI, FABIO;CINQUINI, CARLO
1996-01-01

Abstract

The major limitation implicit in the endovascular procedures for aortic prosthetic substitution is that they cannot be used in these tracts of the aorta where important collateral branches originate (aortic arch, thoraco-abdominal tract, upper abdominal), that would be occluded by the prosthesis. In order to overcome this limitation we hypothesized the endovascular positioning of a prosthesis in the form of a wide mesh network that would be gradually and spontaneously covered by new intima and included in the aortic wall. The fabric framework linked to the aortic wall would then condition its significant, regular and uniform mechanical strengthening that fractionates and partially absorbs the centrifuge pulsatile stress of the bloodstream. The purpose of this paper is to report the results of the insertion of a braided Prolene net prosthesis in the first 7 cm of the descending aorta of ten swine. The animals were killed after 6 weeks, the substituted segment removed and aortic wall compliance measured under standardized conditions. The prosthesis was found entirely covered by new intima, well embodied in the aortic wall. The intercostal collateral included in the substituted segment was patent, as proved by bubble formation during underwater insufflation. Compliance of the prosthesis segment was significantly lower than that of the adjacent descending aorta. Histology showed a regular net prosthesis inclusion deep in the neo-intima layer. Present results indicate the technical feasibility of the procedure, achieving significant aortic wall. strengthening without affecting the collateral (intercostal) circulation.
1996
Engineering Mathematics covers resources on applied mathematics, mathematical modelling, combinatorics, optimization techniques, numerical methods, and statistical methods that have an emphasis on engineering systems.
Comitato scientifico
Inglese
Internazionale
STAMPA
10
4
264
272
9
aneurysm; dissection; thoracic aorta; Marfan's disease
no
8
info:eu-repo/semantics/article
262
Nazari, S; Luzzana, F; Carli, Fabio; Mourad, Z; Guagliano, A; Banfi, C; Salvi, S; Cinquini, Carlo
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/449825
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact