Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instru- ments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.

Antibacterial efficacy of conventional and single-use Ni-Ti endodontic instruments: an in vitro microbiological evaluation

VISAI, LIVIA;COLOMBO, MARCO;BIANCHI, STEFANO;POGGIO, CLAUDIO
2012-01-01

Abstract

Purpose: The purpose of this in vitro study was to investigate the capability of different Ni-Ti instru- ments in disinfecting root canals previously infected with E. faecalis. Methods: 60 single-rooted, freshly extracted teeth were selected, sterilized and inoculated with cells of E. faecalis strain. All root canals were shaped with different Ni-Ti instruments (MTwo, Revo-S, Reciproc, and OneShape) under irrigation with NaOCl and 17% EDTA solutions by the same trained operator. The number of Colony Forming Units (CFU)/ml of E. faecalis was evaluated for each group. Numeric data were submitted to statistical analysis. Results: MTwo, REVO-S, Reciproc and OneShape reported significantly lower CFU/ml values and showed no significant differences among them (p>0.05). All groups showed significantly higher CFU/ ml values than not treated samples (negative control). Conclusions: All the Ni-Ti instrumentation efficiently reduced E. faecalis counts and no significant differences were found among them. Single-use files can offer antibacterial results comparable with traditional instruments.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/576345
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
social impact