Vestibular evoked myogenic potentials (VEMPs) are myogenic responses induced by stimulation of the saccular macula by intense sound stimuli, The responses are recordable from the sternocleidomastoid (SCM) muscles. We recorded VEMPs from normal subjects (up to three times in each subject) to identify: i) the best recording procedures, ii) the reliability. and iii) the normal limits for both individual point and test-retest evaluation. We adopted a recording setting in which the subjects were asked to simultaneously activate both SCM muscles by pushing their forehead against a load cell during a bilateral acoustic stimulation. This system enabled subjects to monitor their intensity of SCM activation and to keep intensity constant: us to record VEMPs from both sides simultaneously. and thus to minimize the duration of the recording session. For each subject we considered the mean and the difference (divided by the mean) of the values derived from the two SCM muscles of the latency of the P13 and N23 components and of the P13-N23 peak-to-peak amplitude. Reliability was evaluated by estimate of the intraclass correlation coefficient, and was good or excellent for all parameters. with the exception of the P13-N23 amplitude side-difference. To take advantage of all the data available, we computed the normal limits for both individual point and test-retest evaluation by means of the variability indices used for the evaluation of reliability. In this system, VEMP recording is simple, inexpensive and rapid. It is well tolerated by subjects, and easily implemented in laboratories equipped for evoked potential recording.

Vestibular evoked myogenic potentials:test-retest reliability.

VERSINO, MAURIZIO;COLNAGHI, SILVIA;CALLIECO, ROBERTO;COSI, VITTORIO
2001-01-01

Abstract

Vestibular evoked myogenic potentials (VEMPs) are myogenic responses induced by stimulation of the saccular macula by intense sound stimuli, The responses are recordable from the sternocleidomastoid (SCM) muscles. We recorded VEMPs from normal subjects (up to three times in each subject) to identify: i) the best recording procedures, ii) the reliability. and iii) the normal limits for both individual point and test-retest evaluation. We adopted a recording setting in which the subjects were asked to simultaneously activate both SCM muscles by pushing their forehead against a load cell during a bilateral acoustic stimulation. This system enabled subjects to monitor their intensity of SCM activation and to keep intensity constant: us to record VEMPs from both sides simultaneously. and thus to minimize the duration of the recording session. For each subject we considered the mean and the difference (divided by the mean) of the values derived from the two SCM muscles of the latency of the P13 and N23 components and of the P13-N23 peak-to-peak amplitude. Reliability was evaluated by estimate of the intraclass correlation coefficient, and was good or excellent for all parameters. with the exception of the P13-N23 amplitude side-difference. To take advantage of all the data available, we computed the normal limits for both individual point and test-retest evaluation by means of the variability indices used for the evaluation of reliability. In this system, VEMP recording is simple, inexpensive and rapid. It is well tolerated by subjects, and easily implemented in laboratories equipped for evoked potential recording.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/9119
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 49
social impact