The choice of the interface for noninvasive ventilation (NIV) is a key factor in NIV success. We hypothesised that a new helmet specifically design to improve performance in hypercapnic patients would be clinically equivalent to a standard oronasal mask. In a multicentre, short-term, physiological, randomised trial in chronic obstructive pulmonary disease patients facing an acute hypercapnic respiratory failure episode, we compared the changes in arterial blood gases (ABGs) and tolerance score obtained using the helmet or mask, and, as secondary end-points, dyspnoea, vital signs, early NIV discontinuation and rate of intubation. 80 patients were randomly assigned to receive NIV either with the helmet (n=39) or mask (n=41), using an intensive care unit ventilator. Compared with baseline, in the first 6 h, NIV improved ABGs, dyspnoea and respiratory rate (p<0.05) in both groups. Changes in ABGs and discomfort were similar with the two groups, while dyspnoea decreased more (p<0.005) using the mask. The rate of intubation and the need for interface change during the whole period of NIV were very low and not different between groups. The new helmet may be a valid alternative to a mask in improving ABGs and achieving a good tolerance during an episode of acute hypercapnic respiratory failure.

Oro-nasal mask versus helmet in acute hypercapnic respiratory failure

GRASSI, MARIO;
2015-01-01

Abstract

The choice of the interface for noninvasive ventilation (NIV) is a key factor in NIV success. We hypothesised that a new helmet specifically design to improve performance in hypercapnic patients would be clinically equivalent to a standard oronasal mask. In a multicentre, short-term, physiological, randomised trial in chronic obstructive pulmonary disease patients facing an acute hypercapnic respiratory failure episode, we compared the changes in arterial blood gases (ABGs) and tolerance score obtained using the helmet or mask, and, as secondary end-points, dyspnoea, vital signs, early NIV discontinuation and rate of intubation. 80 patients were randomly assigned to receive NIV either with the helmet (n=39) or mask (n=41), using an intensive care unit ventilator. Compared with baseline, in the first 6 h, NIV improved ABGs, dyspnoea and respiratory rate (p<0.05) in both groups. Changes in ABGs and discomfort were similar with the two groups, while dyspnoea decreased more (p<0.005) using the mask. The rate of intubation and the need for interface change during the whole period of NIV were very low and not different between groups. The new helmet may be a valid alternative to a mask in improving ABGs and achieving a good tolerance during an episode of acute hypercapnic respiratory failure.
2015
The Cardiovascular & Respiratory Systems category covers resources concerned with all aspects of cardiovascular and thoracic surgery and respiratory diseases. Topics include circulation, cardiovascular technology and measurement, cardiovascular pharmacology and therapy, hypertension, heart and lung transplantation, arteries, arteriosclerosis, thrombosis, angiology, perfusion, stroke, as well as all types of respiratory and lung diseases.
Esperti anonimi
Inglese
Internazionale
STAMPA
45
3
691
699
9
noninvasive ventilation, hypercapnic respiratory failure, RCT, multicenter study
12
info:eu-repo/semantics/article
262
Pisani, L; Mega, C; Vaschetto, R; Bellone, A; Scala, R; Cosentini, R; Musti, M; Del Forno, M; Grassi, Mario; Fasano, L; Navalesi, P; Nava, S.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/989988
Citazioni
  • ???jsp.display-item.citation.pmc??? 27
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 49
social impact