Improving the frame rate is an important aspect in medical ultrasound imaging, particularly in 3D/4D cardiac applications. However, an accurate trade-off between the higher frame rate and image contrast and resolution should be performed. Plane-Wave Imaging (PWI) can potentially achieve frame rates in the order of 10 kHz, as it uses a single unfocused plane wave (and thus a single transmit event) to acquire the image of the entire region of interest. The lack of transmit focusing however causes a significant drop of image quality, which can be restored by coherently compounding several tilted plane-wave frames, at the expense of the frame rate. PWI together with the use of a beamforming algorithm able to achieve a higher image contrast resolution, such as the Delay Multiply And Sum (DMAS), could thus allow to improve image quality achieving a high frame rate at the same time. This paper presents the first simulation results obtained by employing DMAS beamforming and PWI with different transmission angles and coherent compounding. The simulated Point Spread Function (PSF) and cyst-phantom images show that DMAS makes it possible to achieve a high image quality with a reduced number of compounded frames compared to standard Delay And Sum (DAS), and hence it can be used to improve the contrast and resolution of plane-wave images still achieving a very high frame rate. © 2016 IEEE.

Ultrasound plane-wave imaging with delay multiply and sum beamforming and coherent compounding

MATRONE, GIULIA;MAGENES, GIOVANNI
2016-01-01

Abstract

Improving the frame rate is an important aspect in medical ultrasound imaging, particularly in 3D/4D cardiac applications. However, an accurate trade-off between the higher frame rate and image contrast and resolution should be performed. Plane-Wave Imaging (PWI) can potentially achieve frame rates in the order of 10 kHz, as it uses a single unfocused plane wave (and thus a single transmit event) to acquire the image of the entire region of interest. The lack of transmit focusing however causes a significant drop of image quality, which can be restored by coherently compounding several tilted plane-wave frames, at the expense of the frame rate. PWI together with the use of a beamforming algorithm able to achieve a higher image contrast resolution, such as the Delay Multiply And Sum (DMAS), could thus allow to improve image quality achieving a high frame rate at the same time. This paper presents the first simulation results obtained by employing DMAS beamforming and PWI with different transmission angles and coherent compounding. The simulated Point Spread Function (PSF) and cyst-phantom images show that DMAS makes it possible to achieve a high image quality with a reduced number of compounded frames compared to standard Delay And Sum (DAS), and hence it can be used to improve the contrast and resolution of plane-wave images still achieving a very high frame rate. © 2016 IEEE.
2016
978-145770220-4
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1174882
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 43
social impact