In this paper we present a position-sensitive detector based on the vertical integration of pairs of aligned pixels operating in Geiger-mode regime and designed for charged particle detection. This novel device exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. This concept allows to have a reduced material budget and low power consumption in spite of a high granularity and fast timing response. A proof-of-principle prototype was designed and fabricated in a 150 nm CMOS process and vertically integrated through bump bonding. This first demonstrator has been characterized and tested with a high energy particle beams at CERN SPS/PS facilities, in different configurations, featuring a reduction of the dark-count rate (DCR) at room temperature from ∼100 kHz/mm2 to about 24 Hz/mm2 a particle detection efficiency limited only by the geometric factor. The device radiation tolerance has been investigated, via irradiation of single tiers with 10 keV X-rays up to a dose of 1 Mrad (SiO2) and with neutrons up to a fluence of 1011 cm−2. A second prototype, addressing the goal to improve the present fill-factor, has been designed, manufactured and approaches now the characterization phase. Potential applications of this sensor include high spatial resolution tracking in high-energy experiments, radiation monitoring in space and radiation imaging in nuclear medicine. A small hand-held demonstrator is under construction for radio-guided surgery.

APiX, a two-tier avalanche pixel sensor for digital charged particle detection

Musacci M.;Torilla G.;Ratti L.;Vacchi C.;
2019-01-01

Abstract

In this paper we present a position-sensitive detector based on the vertical integration of pairs of aligned pixels operating in Geiger-mode regime and designed for charged particle detection. This novel device exploits the coincidence between two simultaneous avalanche events to discriminate between particle-triggered detections and dark counts. This concept allows to have a reduced material budget and low power consumption in spite of a high granularity and fast timing response. A proof-of-principle prototype was designed and fabricated in a 150 nm CMOS process and vertically integrated through bump bonding. This first demonstrator has been characterized and tested with a high energy particle beams at CERN SPS/PS facilities, in different configurations, featuring a reduction of the dark-count rate (DCR) at room temperature from ∼100 kHz/mm2 to about 24 Hz/mm2 a particle detection efficiency limited only by the geometric factor. The device radiation tolerance has been investigated, via irradiation of single tiers with 10 keV X-rays up to a dose of 1 Mrad (SiO2) and with neutrons up to a fluence of 1011 cm−2. A second prototype, addressing the goal to improve the present fill-factor, has been designed, manufactured and approaches now the characterization phase. Potential applications of this sensor include high spatial resolution tracking in high-energy experiments, radiation monitoring in space and radiation imaging in nuclear medicine. A small hand-held demonstrator is under construction for radio-guided surgery.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1314806
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact