Boron Neutron Capture Therapy (BNCT) is an experimental radio-therapy that uses the combination of neutron irradiation and 10 B to treat neoplasms. By means of this technique, many clinical trials were performed worldwide with promising results [1] using research nuclear reactors as neutron sources. Anyhow, these machines have several problems that hinder the development of dedicatedBNCT hospitals. This issue can now be overcome by using intense-current proton accelerators, which coupled with beryllium or lithium targets yield more than 1014neutron per second. This can be a boost to BNCT because accelerators are more compact and can be installed within hospitals.The Italian National Institute of Nuclear Physics (INFN) designed and manufactured a Radiofrequency Quadrupole proton accelerator(RFQ) [2], which delivers 5 MeV protons with 30 mA current in aContinuous Wave (CW) mode and it is coupled to a beryllium target.This accelerator could be installed at Centro Nazionale di Adrotherapia Oncologica (CNAO) in Pavia.In this work we present the MC calculations for the tailoring of aBNCT neutron beam obtained by the described RFQ. Firstly, we show that MC transport codes such as MCNP and PHITS are not able to simulate the correct neutron spectra from 5 MeV protons interacting on beryllium. Therefore, the neutron double differential source implemented in MCNP was extracted from the measurements per-formed by Agosteo et al. [3]. As the energy range goes up to3.5 MeV, neutrons need to be moderated and collimated by a BeamShaping Assembly (BSA), because BNCT requires a spectrum peaked between 1 and 10 keV. Differently from the past, where the optimal configuration was chosen according to physical characteristics of the beam, in this case the results were evaluated on the basis of the dosimetry obtained in a real clinical case by treatment planning simulation. What emerges, is that the classical figures of merit employed for the tailoring of a clinical BNCT [4] should be taken as a first guideline, while the dosimetric assessment on realistic clinical scenarios is the most appropriate criterion for beam evaluations

Abstract ID: 51 Monte Carlo optimization of a neutron beam from 5 MeV 9Be(p,n) 9B reaction for clinical BNCT

I. Postuma;S. Bortolussi;N. Protti;S. Altieri
2017-01-01

Abstract

Boron Neutron Capture Therapy (BNCT) is an experimental radio-therapy that uses the combination of neutron irradiation and 10 B to treat neoplasms. By means of this technique, many clinical trials were performed worldwide with promising results [1] using research nuclear reactors as neutron sources. Anyhow, these machines have several problems that hinder the development of dedicatedBNCT hospitals. This issue can now be overcome by using intense-current proton accelerators, which coupled with beryllium or lithium targets yield more than 1014neutron per second. This can be a boost to BNCT because accelerators are more compact and can be installed within hospitals.The Italian National Institute of Nuclear Physics (INFN) designed and manufactured a Radiofrequency Quadrupole proton accelerator(RFQ) [2], which delivers 5 MeV protons with 30 mA current in aContinuous Wave (CW) mode and it is coupled to a beryllium target.This accelerator could be installed at Centro Nazionale di Adrotherapia Oncologica (CNAO) in Pavia.In this work we present the MC calculations for the tailoring of aBNCT neutron beam obtained by the described RFQ. Firstly, we show that MC transport codes such as MCNP and PHITS are not able to simulate the correct neutron spectra from 5 MeV protons interacting on beryllium. Therefore, the neutron double differential source implemented in MCNP was extracted from the measurements per-formed by Agosteo et al. [3]. As the energy range goes up to3.5 MeV, neutrons need to be moderated and collimated by a BeamShaping Assembly (BSA), because BNCT requires a spectrum peaked between 1 and 10 keV. Differently from the past, where the optimal configuration was chosen according to physical characteristics of the beam, in this case the results were evaluated on the basis of the dosimetry obtained in a real clinical case by treatment planning simulation. What emerges, is that the classical figures of merit employed for the tailoring of a clinical BNCT [4] should be taken as a first guideline, while the dosimetric assessment on realistic clinical scenarios is the most appropriate criterion for beam evaluations
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/1321586
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact