Background: PAP is an ultra-rare respiratory syndrome characterized by the accumulation of surfactant within the alveoli. Whole lung lavage (WLL) is the current standard of care of PAP, however it is not a standardized procedure and the total amount of fluid used to wash each lung is still debated. Considering ICU hospitalization associated risks, a “mini-WLL” with anticipated manual clapping and reduced total infusion volume and has been proposed in our center. The aim of the study is to retrospectively analyze the efficacy of mini-WLL compared to standard WLL at the Pavia center. Methods: 13 autoimmune PAP patients eligible for WLL were included: 7 patients were admitted to mini-WLL (9 L total infusion volume for each lung) and 6 patients underwent standard WLL (14 L of infusion volume). Functional data (VC%, FVC%, TLC%, DLCO%) and alveolar-arterial gradient values (A-aO2) were collected at the baseline and 1, 3, 6, 12, 18 months after the procedure. Results: A statistically significant improvement of VC% (p = 0.013, 95%CI 3.49–30.19), FVC% (p = 0.016, 95%CI 3.37–32.09), TLC% (p = 0.001, 95%CI 7.38–30.34) was observed in the mini-WLL group in comparison with the standard WLL group, while no significant difference in DLCO% and A-aO2 mean values were reported. Conclusion: Mini-WLL has demonstrated higher efficacy in ameliorating lung volumes, suggesting that a lower infusion volume is sufficient to remove the surfactant accumulation and possibly allows a reduced mechanical insult of the bronchi walls and the alveoli. However, no statistically significant differences were found in terms of DLCO% and Aa-O2.
A mini-whole lung lavage to treat autoimmune pulmonary alveolar proteinosis (PAP)
Salvaterra, Elena;Lettieri, Sara;De Silvestri, Annalisa;Corino, Alessandra;Bosio, Matteo;Fraolini, Elia;Piloni, Davide;Corsico, Angelo Guido;Campo, Ilaria
2022-01-01
Abstract
Background: PAP is an ultra-rare respiratory syndrome characterized by the accumulation of surfactant within the alveoli. Whole lung lavage (WLL) is the current standard of care of PAP, however it is not a standardized procedure and the total amount of fluid used to wash each lung is still debated. Considering ICU hospitalization associated risks, a “mini-WLL” with anticipated manual clapping and reduced total infusion volume and has been proposed in our center. The aim of the study is to retrospectively analyze the efficacy of mini-WLL compared to standard WLL at the Pavia center. Methods: 13 autoimmune PAP patients eligible for WLL were included: 7 patients were admitted to mini-WLL (9 L total infusion volume for each lung) and 6 patients underwent standard WLL (14 L of infusion volume). Functional data (VC%, FVC%, TLC%, DLCO%) and alveolar-arterial gradient values (A-aO2) were collected at the baseline and 1, 3, 6, 12, 18 months after the procedure. Results: A statistically significant improvement of VC% (p = 0.013, 95%CI 3.49–30.19), FVC% (p = 0.016, 95%CI 3.37–32.09), TLC% (p = 0.001, 95%CI 7.38–30.34) was observed in the mini-WLL group in comparison with the standard WLL group, while no significant difference in DLCO% and A-aO2 mean values were reported. Conclusion: Mini-WLL has demonstrated higher efficacy in ameliorating lung volumes, suggesting that a lower infusion volume is sufficient to remove the surfactant accumulation and possibly allows a reduced mechanical insult of the bronchi walls and the alveoli. However, no statistically significant differences were found in terms of DLCO% and Aa-O2.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.