The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\mu}m and a relative momentum resolution {\sigma}p/p = (4.83+/-0.16) \times 10-4 GeV-1 \times pT have been measured for high momentum tracks.

The ATLAS Inner Detector commissioning and calibration

CONTA, CLAUDIO;FRANCHINO, SILVIA;FRATERNALI, MARCO;GAUDIO, GABRIELLA;LIVAN, MICHELE;NEGRI, ANDREA;REBUZZI, DANIELA MARCELLA;RIMOLDI, ADELE;USLENGHI, MASSIMILIANO
2010-01-01

Abstract

The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\mu}m and a relative momentum resolution {\sigma}p/p = (4.83+/-0.16) \times 10-4 GeV-1 \times pT have been measured for high momentum tracks.
2010
The Physics category includes resources of a broad, general nature that contain materials from all areas of physics, The category also includes resources specifically concerned with the following physics sub-fields: mathematical physics, particle and nuclear physics, physics of fluids and plasmas, quantum physics, and theoretical physics.
Sì, ma tipo non specificato
Inglese
Internazionale
STAMPA
70
787
821
ATLAS; LHC
9
info:eu-repo/semantics/article
262
Conta, Claudio; Franchino, Silvia; Fraternali, Marco; Gaudio, Gabriella; Livan, Michele; Negri, Andrea; Rebuzzi, DANIELA MARCELLA; Rimoldi, Adele; Usl...espandi
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11571/279505
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact